| поискавой системы для электроныых деталей |
|
PC87591L датащи(PDF) 183 Page - National Semiconductor (TI) |
|
|
|
|||||||||||||||||||||||||||||
PC87591L датащи(HTML) 183 Page - National Semiconductor (TI) |
|
183 / 437 page ![]() Embedded Controller Modules (Continued) Revision 1.07 183 www.national.com Voltage Channel 1 Control Register (VCHN1CTL) This register both controls the operation and indicates the status of Voltage Channel 1. VCHN1CTL is set to 1F16 on reset. Location: 00 FF3416 Type: Varies per bit Bit 76543210 Name DATVAL CSCALE INTDVEN SELIN Reset 00011111 Bit Type Description 4-0 R/W SELIN (Selected Input). Selects a voltage input to be measured during the next ADC cycle. The new value should be set before the beginning of the channel measurement. When read, this field indicates to which input the contents of the channel data buffer belongs. When written, it selects a new input for the next channel measurement. See Figure 60 on page 172 for details on the channel input signals connection to pins. The channel is disabled by setting this field to 111112. When disabled, the channel is “skipped”, enabling a higher measurement rate for the remaining channels (shorter ADC cycle). The DATVAL bit is cleared Bits 4 3 2 1 0 Description 0 0 0 0 0: Channel 0 0 0 0 0 1: Channel 1 .... 0 1 0 0 0: Channel 8 (Available when REMDEN bit in ADCCNF register is cleared) 0 1 0 0 1: Channel 9 (Available when REMDEN bit in ADCCNF register is cleared) 0 1 0 1 0: Channel 10 .... 0 1 1 0 1: Channel 13 Other: Reserved 1 1 1 1 1: Channel Disabled (default) 5 R/W INTDVEN (Interrupt from Data Valid Enable). Enables generation of an ADC interrupt on a Voltage Channel 1, Data Valid event (End-of-conversion). 0: Disabled (default) 1: Enabled - ADC Interrupt from local DATVAL 6 R/W CSCALE (Channel Scale). Controls the input scale of the input for the channel to be converted (as selected by SELIN field). 0: Channel uses the high range scale (default) 1: Channel uses the low range scale 7 R/W1C DATVAL (Data Valid). Voltage Channel 1 Data Buffer contains new data. The data may be read immediately or at the end-of-cycle. This flag is cleared when the channel is disabled, when the ADC module is disabled (ADCEN in ADCCNF register is cleared) or by a write of 1 to it. 0: No new valid data in VCHN1DAT register (default) 1: End of conversion - new data is available in the buffer |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |