Back Button LP3971 Datasheet HTML 12Page - Texas Instruments LP3971 Datasheet HTML 13Page - Texas Instruments LP3971 Datasheet HTML 14Page - Texas Instruments LP3971 Datasheet HTML 15Page - Texas Instruments LP3971 Datasheet HTML 16Page - Texas Instruments LP3971 Datasheet HTML 17Page - Texas Instruments LP3971 Datasheet HTML 18Page - Texas Instruments LP3971 Datasheet HTML 19Page - Texas Instruments LP3971 Datasheet HTML 20Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 16 / 52 page
background image
LP3971
SNVS432V – JANUARY 2006 – REVISED MAY 2013
www.ti.com
I
2C Compatible Serial Interface Electrical Specifications (SDA and SCL)
Unless otherwise noted, VIN = 3.6V. Typical values and limits appearing in normal type apply for TJ = 25°C. Limits appearing
in boldface type apply over the entire junction temperature range for operation,
−40°C to +125°C.
(1) (2) and (3)
Symbol
Parameter
Conditions
Min
Typ
Max
Units
VIL
Low Level Input Voltage
(4)
−0.5
0.3
V
VRTC
VIH
High Level Input Voltage
(4)
0.7
VRTC
VRTC
VOL
Low Level Output Voltage
(4)
0
0.2
VTRC
IOL
Low Level Output Current
VOL = 0.4V
(4)
3.0
mA
FCLK
Clock Frequency
(4)
400
kHz
tBF
Bus-Free Time Between Start and Stop
(4)
1.3
μs
tHOLD
Hold Time Repeated Start Condition
(4)
0.6
μs
tCLKLP
CLK Low Period
(4)
1.3
μs
tCLKHP
CLK High Period
(4)
0.6
μs
tSU
Set Up Time Repeated Start Condition
(4)
0.6
μs
tDATAHLD
Data Hold Time
(4)
0
μs
tCLKSU
Data Set Up Time
(4)
100
ns
TSU
Set Up Time for Start Condition
(4)
0.6
μs
TTRANS
Maximum Pulse Width of Spikes that Must
(4)
50
ns
be Suppressed by the Input Filter of Both
DATA & CLK Signals
(1)
All voltages are with respect to the potential at the GND pin.
(2)
All limits specified at room temperature and at temperature extremes. All room temperature limits are production tested, specified
through statistical analysis or by design. All limits at temperature extremes are specified via correlation using standard Statistical Quality
Control (SQC) methods. All limits are used to calculate Average Outgoing Quality Level (AOQL).
(3)
The I2C signals behave like open-drain outputs and require an external pull-up resistor on the system module in the 2 k
Ω to 20 kΩ
range.
(4)
Specified by design. Not production tested
16
Submit Documentation Feedback
Copyright © 2006–2013, Texas Instruments Incorporated
Product Folder Links: LP3971



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52


датащи скачать

Go To PDF Page


ссылки URL



Вашему бизинису помогли Аллдатащит?  [ DONATE ] 

Что такое Аллдатащит   |   реклама   |   контакт   |   Конфиденциальность   |   Ссылка на техническое описание    |   обмен ссыками   |   поиск по производителю
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com