| поискавой системы для электроныых деталей |
|
LM3560TLX/NOPB датащи(PDF) 21 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
LM3560TLX/NOPB датащи(HTML) 21 Page - Texas Instruments |
|
21 / 48 page ![]() tBLANK (15.24s) tPERIOD tPERIOD tPERIOD (1.016s) (1.016s) (1.016s) tACTIVE (3.048s) tPERIOD tBLANK (5.08s) (1.016s) IIND tBLANK tR tF tPULSE tPULSE tPERIOD tR tF tPULSE tPULSE tPERIOD LM3560 www.ti.com SNOSB43B – SEPTEMBER 2011 – REVISED AUGUST 2013 Figure 32. Message Indicator Timing Diagram MESSAGE INDICATOR EXAMPLE 1 (Single Pulse with Dead Time): As an example, to set up the message indicator for a 312 ms ramp-up and ramp-down, 192 ms pulse width, and 1 pulse followed by a 5s delay. The indicator settings will be as follows. tR = tF = 312 ms, tWIDTH = 192 ms (tPERIOD = 312 ms x 2 + 192 ms x 2 = 1016 ms). BLANK# setting will be: 5s/1016 ms x 1 (PERIOD# = 1). Giving a BLANK# setting of 5. The resulting waveform will appear as: Figure 33. Message Indicator Example 1 MESSAGE INDICATOR EXAMPLE 2 (Multiple Pulses with Dead Time): Another example has the same tR, tF, tPULSE, and tBLANK times as before, but this time the PERIOD# is set to 3. Now the tACTIVE time is tPERIOD × 3 = 1016 ms × 3 = 3048 ms. This results in a blank time of tBLANK = tACTIVE × BLANK# = 3.048s × 5 = 15.24s Figure 34. Message Indicator Example 2 UPDATING THE MESSAGE INDICATOR The best way to update the message indicator is to disable the Message Indicator output via the Enable Register bit [6], then write the new sequence to the Indicator Register and/or Indicator Blinking Register, and then re- enable the Message Indicator. Updating the Indicator Registers while it is active can lead to long delays between pattern changes. This is especially true if the PERIOD#, or BLANK# setting is changed from a high setting to a lower setting. NTC MODE Writing a (1) to Configuration Register 1 bit [4] configures the LEDI/NTC pin for NTC mode. In this mode the indicator current source is disabled, and LEDI/NTC becomes the positive input to the an internal comparator. NTC mode operates as a LED current interrupt that is triggered when the voltage at LEDI/NTC goes below 1V. Copyright © 2011–2013, Texas Instruments Incorporated Submit Documentation Feedback 21 Product Folder Links: LM3560 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |