| поискавой системы для электроныых деталей |
|
WM8998 датащи(PDF) 86 Page - Wolfson Microelectronics plc |
|
|
|||||||||||||||||||||||||||||
WM8998 датащи(HTML) 86 Page - Wolfson Microelectronics plc |
|
86 / 307 page ![]() WM8998 Production Data w PD, October 2014, Rev 4.0 86 The PWM sample rate (cycle time) is configured using the PWM_RATE register - see Table 19. Note that sample rate conversion is required when linking the PWM generators to any signal chain that is asynchronous and/or configured for a different sample rate. The PWM generators are enabled using PWM1_ENA and PWM2_ENA respectively, as described in Table 18. Under default conditions (PWMn_OVD = 0), the duty cycle of the PWM generators is controlled by an audio signal path; a 4-input mixer is associated with each PWM generator, as illustrated in Figure 32. When the PWMn_OVD bit is set, the duty cycle of the respective PWM generator is set to a fixed ratio; in this case, the duty cycle ratio is configurable using the PWMn_LVL registers. The PWM generator clock frequency is selected using PWM_CLK_SEL. For best performance, this register should be set to the highest available setting. Note that the PWM generator clock must not be set to a higher frequency than SYSCLK (if PWM_RATE<1000) or ASYNCCLK (if PWM_RATE≥1000). REGISTER ADDRESS BIT LABEL DEFAULT DESCRIPTION R48 (0030h) PWM Drive 1 10:8 PWM_CLK_SEL [2:0] 000 PWM Clock Select 000 = 6.144MHz (5.6448MHz) 001 = 12.288MHz (11.2896MHz) 010 = 24.576MHz (22.5792MHz) All other codes are Reserved The frequencies in brackets apply for 44.1kHz-related sample rates only. PWM_CLK_SEL controls the resolution of the PWM generator; higher settings correspond to higher resolution. The PWM Clock must be less than or equal to SYSCLK (if PWM_RATE<1000) or less than or equal to ASYNCCLK (if PWM_RATE>=1000). 5 PWM2_OVD 0 PWM2 Generator Override 0 = Disabled (PWM duty cycle is controlled by audio source) 1 = Enabled (PWM duty cycle is controlled by PWM2_LVL). 4 PWM1_OVD 0 PWM1 Generator Override 0 = Disabled (PWM1 duty cycle is controlled by audio source) 1 = Enabled (PWM1 duty cycle is controlled by PWM1_LVL). 1 PWM2_ENA 0 PWM2 Generator Enable 0 = Disabled 1 = Enabled 0 PWM1_ENA 0 PWM1 Generator Enable 0 = Disabled 1 = Enabled R49 (0031h) PWM Drive 2 9:0 PWM1_LVL [9:0] 100h PWM1 Override Level Sets the PWM1 duty cycle when PWM1_OVD=1. Coded as 2’s complement. 000h = 50% duty cycle 100h = 0% duty cycle R50 (0032h) PWM Drive 3 9:0 PWM2_LVL [9:0] 100h PWM2 Override Level Sets the PWM2 duty cycle when PWM2_OVD=1. Coded as 2’s complement. 000h = 50% duty cycle 100h = 0% duty cycle Table 18 Pulse Width Modulation (PWM) Generator Control |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |