| поискавой системы для электроныых деталей |
|
L9779WD датащи(PDF) 123 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
L9779WD датащи(HTML) 123 Page - STMicroelectronics |
|
123 / 170 page ![]() DocID027452 Rev 5 123/170 L9779WD Functional description 169 REQUHI (upstream data block8, read command: RD_DATA8) REQUHI REQUEST HI Address: - Type: R Reset: 1100 0000b (reset source: RST_UV, Bit 4 additionally RST_PRL) 7 6 5 43210 RESP_CNT1 RESP_CNT0 RESP_ERR RESP_Z0 CHRT W_RESP NO_RESP RESP_TO_EAR LY R [7-6] RESP_CNT(1-0): Counter for receiving the 4 response bytes [5] RESP_ERR: '1': 1 byte of the 32-bit response is incorrect (1) 1. Sequencer-run: A sequencer-run is initiated by the writing of a complete response (RESP_BYTE3…RESP_BYTE0) or by writing of a response-time <RESPTIME> or by reaching the end of a time window. In case WDA reference time base (1/f_clk) has to be changed to f_clk = 39 kHz, CONFIG6 bit1 has to be written to 0 before sequencer-run is started. [4] RESP_Z0: '1': Controller set response-time to 0ms; a correct response within the time window nevertheless increments the error counter by one '0': Response-time is greater than 0ms [3] CHRT: '1': Controller has changed response-time; reset to zero after a read access and after the next sequencer run [2] W_RESP: '1': in case of incorrect response in value; reset to zero at sequencer-run (1) [1] NO_RESP: '1': in case of no response at all; timer is restarted automatically; reset to zero after a read access [0] RESP_TO_EARLY: '1': Response before time window was opened; reset to zero at sequencer-run (1) RESP_TO_EARLY = '1': monitoring module has received a response before beginning of the time window and therefore this was rejected. Reception of a response means "end of reception of RESP_BYTE0" after the other response bytes (i.e. RESP_BYTE3, RESP_BYTE2, RESP_BYTE1 - in this order!) have been received. NO_RESP = '1': monitoring module has received no response at all or a response too late after the time window already closed. However, a response too late might be read as RESP_TO_EARLY, as too late a response is at the same time too early a response concerning the next WDG cycle. This results in the NO_RESP monitoring being overwritten by a RESP_TO_EARLY monitoring. This means that no "end of reception of RESP_BYTE0" was detected before the end of the time window - neither during the time window nor before beginning of the time window. (Remember: RESP_BYTE0 is the last of four response bytes!) |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |