| поискавой системы для электроныых деталей |
|
CAP1208 датащи(PDF) 33 Page - Microchip Technology |
|
|
|||||||||||||||||||||||||||||
CAP1208 датащи(HTML) 33 Page - Microchip Technology |
|
33 / 67 page ![]() 8-Channel Capacitive Touch Sensor Datasheet 2014 Microchip Technology Inc. DS00001570B-page 33 5.4 Sensor Input Delta Count Registers The Sensor Input Delta Count registers store the delta count that is compared against the threshold used to determine if a touch has been detected. The count value represents a change in input due to the capacitance associated with a touch on one of the sensor inputs and is referenced to a calibrated base “not touched” count value. The delta is an instantaneous change and is updated once per sensor input per sensing cycle (see Section 4.3.2, "Sensing Cycle"). The value presented is a standard 2’s complement number. In addition, the value is capped at a value of 7Fh. A reading of 7Fh indicates that the sensitivity settings are too high and should be adjusted accordingly (see Section 5.5). The value is also capped at a negative value of 80h for negative delta counts which may result upon a release. 5.5 Sensitivity Control Register The Sensitivity Control register controls the sensitivity of a touch detection. Bits 6-4 DELTA_SENSE[2:0] - Controls the sensitivity of a touch detection for sensor inputs enabled in the Active state. The sensitivity settings act to scale the relative delta count value higher or lower based on the system parameters. A setting of 000b is the most sensitive while a setting of 111b is the least sensitive. At the more sensitive settings, touches are detected for a smaller delta capacitance Table 5.5 Sensor Input Delta Count Registers ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT 10h R Sensor Input 1 Delta Count Sign 64 32 16 8 4 2 1 00h 11h R Sensor Input 2 Delta Count Sign 64 32 16 8 4 2 1 00h 12h R Sensor Input 3 Delta Count Sign 64 32 16 8 4 2 1 00h 13h R Sensor Input 4 Delta Count Sign 64 32 16 8 4 2 1 00h 14h R Sensor Input 5 Delta Count Sign 64 32 16 8 4 2 1 00h 15h R Sensor Input 6 Delta Count Sign 64 32 16 8 4 2 1 00h 16h R Sensor Input 7 Delta Count Sign 64 32 16 8 4 2 1 00h 17h R Sensor Input 8 Delta Count Sign 64 32 16 8 4 2 1 00h Table 5.6 Sensitivity Control Register ADDR R/W REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT 1Fh R/W Sensitivity Control - DELTA_SENSE[2:0] BASE_SHIFT[3:0] 2Fh |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |