| поискавой системы для электроныых деталей |
|
CAP1208 датащи(PDF) 27 Page - Microchip Technology |
|
|
|||||||||||||||||||||||||||||
CAP1208 датащи(HTML) 27 Page - Microchip Technology |
|
27 / 67 page ![]() 8-Channel Capacitive Touch Sensor Datasheet 2014 Microchip Technology Inc. DS00001570B-page 27 Chapter 5 Register Description The registers shown in Table 5.1 are accessible through the communications protocol. An entry of ‘-’ indicates that the bit is not used and will always read ‘0’. Table 5.1 Register Set in Hexadecimal Order REGISTER ADDRESS R/W REGISTER NAME FUNCTION DEFAULT VALUE PAGE 00h R/W Main Control Controls power states and indicates an interrupt 00h Page 30 02h R/W General Status Stores general status bits 00h Page 31 03h R Sensor Input Status Returns the state of the sampled capacitive touch sensor inputs 00h Page 31 0Ah R Noise Flag Status Stores the noise flags for sensor inputs 00h Page 32 10h R Sensor Input 1 Delta Count Stores the delta count for CS1 00h Page 33 11h R Sensor Input 2 Delta Count Stores the delta count for CS2 00h Page 33 12h R Sensor Input 3 Delta Count Stores the delta count for CS3 00h Page 33 13h R Sensor Input 4 Delta Count Stores the delta count for CS4 00h Page 33 14h R Sensor Input 5 Delta Count Stores the delta count for CS5 00h Page 33 15h R Sensor Input 6 Delta Count Stores the delta count for CS6 00h Page 33 16h R Sensor Input 7 Delta Count Stores the delta count for CS7 00h Page 33 17h R Sensor Input 8 Delta Count Stores the delta count for CS8 00h Page 33 1Fh R/W Sensitivity Control Controls the sensitivity of the threshold and delta counts and data scaling of the base counts 2Fh Page 33 20h R/W Configuration Controls general functionality 20h Page 35 21h R/W Sensor Input Enable Controls which sensor inputs are monitored in Active FFh Page 37 22h R/W Sensor Input Configuration Controls max duration and auto- repeat delay A4h Page 37 23h R/W Sensor Input Configuration 2 Controls the MPRESS (“press and hold”) setting 07h Page 39 24h R/W Averaging and Sampling Config Controls averaging and sampling window for Active 39h Page 40 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |