| поискавой системы для электроныых деталей |
|
Z86L71 датащи(PDF) 30 Page - Zilog, Inc. |
|
|
|||||||||||||||||||||||||||||
Z86L71 датащи(HTML) 30 Page - Zilog, Inc. |
|
30 / 61 page ![]() Z86L70/71/75/C71 IR/Low-Voltage Microcontroller Zilog 1-30 P R E L I M I N A R Y DS97LVO0500 FUNCTIONAL DESCRIPTION (Continued) Input Circuit The edge detector monitors the input signal on P31 or P20. Based on CTR1 D5-D4, a pulse is generated at the Pos Edge or Neg Edge line when an edge is detected. Glitches in the input signal which have a width less than specified (CTR1 D3, D2) are filtered out. T8 Transmit Mode When T8 is enabled, the output of T8 depends on CTR1, D1. If it is 0, T8_OUT is 1. If it is 1, T8_OUT is 0. When T8 is enabled, the output T8_OUT switches to the initial value (CTR1 D1). If the initial value (CTR1 D1) is 0, TC8L is loaded, otherwise TC8H is loaded into the counter. In Single-Pass Mode (CTR0 D6), T8 counts down to 0 and stops, T8_OUT toggles, the time-out status bit (CTR0 D5) is set, and a time-out interrupt can be generat- ed if it is enabled (CTR0 D1) (Figure 22). In Modulo-N Mode, upon reaching terminal count, T8_OUT is toggled, but no interrupt is generated. Then T8 loads a new count (if the T8_OUT level now is 0), TC8L is loaded; if it is 1, TC8H is loaded. T8 counts down to 0, toggles T8_OUT, sets the time-out status bit (CTR0 D5) and generates an interrupt if enabled (CTR0 D1) (Figure 23). This completes one cycle. T8 then loads from TC8H or TC8L according to the T8_OUT level, and repeats the cycle. The user can modify the values in TC8H or TC8L at any time. The new values take effect when they are loaded. Care must be taken not to write these registers at the time the values are to be loaded into the counter/timer, to en- sure known operation. An initial count of 1 is not al- lowed (a non-function will occur). An initial count of 0 will cause TC8 to count from 0 to %FF to %FE (Note, % is used for hexadecimal values). Transition from 0 to %FF is not a time-out condition. Note: Using the same instructions for stopping the counter/timers and setting the status bits is not rec- ommended. Two successive commands, first stopping the counter/timers, then resetting the status bits is neces- sary. This is required because it takes one counter/timer clock interval for the initiated event to actually occur. Figure 19. T8_OUT in Single-Pass Mode TC8H Counts “Counter Enable” Command, T8_OUT Switches To Its Initial Value (CTR1 D1) T8_OUT Toggles, Time-Out Interrupt Figure 20. T8_OUT in Modulo-N Mode “Counter Enable” Command, T8_OUT Switches To Its Initial Value (CTR1 D1) T8_OUT Toggles T8_OUT TC8L TC8H TC8L TC8H TC8L Time-Out Interrupt Time-Out Interrupt |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |