| поискавой системы для электроныых деталей |
|
Z86L71 датащи(PDF) 24 Page - Zilog, Inc. |
|
|
|||||||||||||||||||||||||||||
Z86L71 датащи(HTML) 24 Page - Zilog, Inc. |
|
24 / 61 page ![]() Z86L70/71/75/C71 IR/Low-Voltage Microcontroller Zilog 1-24 P R E L I M I N A R Y DS97LVO0500 CTR0 (D)00: Counter/Timer8 Control Register. CTR0: Counter/Timer8 Control Register Description T8 Enable. This field enables T8 when set (written) to 1. Single/Modulo-N. When set to 0 (modulo-n), the counter reloads the initial value when the terminal count is reached. When set to 1 (single pass), the counter stops when the terminal count is reached. Time-Out. This bit is set when T8 times out (terminal count reached). To reset this bit, a 1 should be written to this lo- cation. This is the only way to reset this status condition, therefore, care should be taken to reset this bit prior to us- ing/enabling the counter/timers. Note: Care must be taken when utilizing the OR or AND commands to manipulate CTR0, bit 5 and CTR1, bits 0 and 1 (Demodulation Mode). These instructions use a Read-Modify-Write sequence in which the current status from the CTR0 and CTR1 registers will be ORed or ANDed with the designated value and then written back into the registers. Example: When the status of bit 5 is 1, a reset condition will occur. T8 Clock. Defines the frequency of the input signal to T8. Capture_INT_Mask. Set this bit to allow interrupt when data is captured into either LO8 or HI8 upon a positive or negative edge detection in demodulation mode. Counter_INT_Mask. Set this bit to allow interrupt when T8 has a time out. P34_Out. This bit defines whether P34 is used as a normal output pin or the T8 output. Field Bit Position Value Description T8_Enable 7------- R W 0* 1 0 1 Counter Disabled Counter Enabled Stop Counter Enable Counter Single/Modulo-N -6------ R/W 0 1 Modulo-N Single Pass Time_Out --5----- R 0 No Counter Time-Out Counter Time-Out Occurred No Effect Reset Flag to 0 T8_Clock ---43--- R/W 0 0 0 1 1 0 1 1 SCLK SCLK/2 SCLK/4 SCLK/8 Capture_INT_Mask -----2-- R/W 0 1 Disabled Data Capture Int. Enable Data Capture Int. Counter_INT_Mask ------1- R/W 0 1 Disable Data Capture Int. Enable Time-Out Int. P34_Out -------0 R/W 0 1 P34 as Port Output T8 Output on P34 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |