| поискавой системы для электроныых деталей |
|
DB929B датащи(PDF) 20 Page - CML Microcircuits |
|
|
|||||||||||||||||||||||||||||
DB929B датащи(HTML) 20 Page - CML Microcircuits |
|
20 / 51 page ![]() 4-Level FSK Modem Data Pump Page 20 of 50 MX929B PRELIMINARY INFORMATION ©2001 MX-COM, INC. www.mxcom.com Tel: 800 638 5577 336 744 5050 Fax: 336 744 5054 Doc. # 20480171.003 4800 Bethania Station Road, Winston-Salem, NC 27105-1201 USA All trademarks and service marks are held by their respective companies. 4.5.2.9 RHB: Read Header Block This task causes the modem to read the next 69 symbols as a 'Header' Block. It will strip out the 'S' symbols then de-interleave and decode the remaining 66 symbols, placing the resulting 10 data bytes and the 2 received CRC1 bytes into the Data Block Buffer and, when the task is complete, setting the BFREE and IRQ bits of the Status Register to '1'to indicate that the µC may read the data from the Data Block Buffer and write the next task to the modem's Command Register. The CRCERR bit of the Status Register will be set to '1' or '0' depending on the validity of the received CRC1 checksum bytes. As each of the three 'S' symbols of a block is received, the SVAL bits of the Status Register will be updated and the SRDY bit set to '1'. (If the SSIEN bit of the Mode Register is '1', then the Status Register IRQ bit will also be set to '1'.) Note that when the third 'S' symbol is received, the SRDY bit will be set to '1' coincidentally with the BFREE bit also being set to '1'. 4.5.2.10 RILB: Read 'Intermediate' or 'Last' Block This task causes the modem to read the next 69 symbols as an 'Intermediate' or 'Last' block. (The µC can tell from the 'Header' block how many blocks are in the frame and therefore when to expect the 'Last' block). In each case, it will strip out the three 'S' symbols, de-interleave, and decode the remaining 66 symbols and place the resulting 12 bytes into the Data Block Buffer, setting the BFREE and IRQ bits of the Status Register to '1' when the task is complete. If an 'Intermediate' block is received, then the µC should read out all 12 bytes from the Data Block Buffer and ignore the CRCERR bit of the Status Register. For a 'Last' block the µC need only read the first 8 bytes from the Data Block Buffer, and the CRCERR bit in the Status Register will reflect the validity of the received CRC2 checksum. As each of the three 'S' symbols of the block is received, the SVAL bits of the Status Register will be updated and the SRDY bit set to '1'. (If the SSIEN bit of the Mode Register is '1', then the Status Register IRQ bit will also be set to '1'.) Note that when the third 'S' symbol is received, the SRDY bit will be set to '1' coincidentally with the BFREE bit also being set to '1'. 4.5.2.11 SFS: Search for Frame Sync This task, which is intended for special test and channel monitoring purposes, performs the first two parts only of a SFP task. It causes the modem to search the received signal for a 24-symbol sequence, which matches the required Frame Synchronization pattern to within the tolerance defined by the FSTOL bits of the Mode Register. When a match is found the modem will read in the following 'S' symbol, then set the BFREE, IRQ, and SRDY bits of the Status Register to '1' and update the SVAL bits. The µC may then write the next task to the Command Register. 4.5.2.12 R4S: Read 4 Symbols This task causes the modem to read the next 4 symbols and translate them directly (without de-interleaving or FEC) to an 8-bit byte which is placed into the Data Block Buffer. The BFREE and IRQ bits of the Status Register are then set to '1' to indicate that the µC may read the data byte from the Data Block Buffer and write the next task to the Command Register. This task is intended for special tests and channel monitoring - perhaps preceded by a SFS task. Note: It is possible to construct message formats, which do not rely on the block formatting of the THB, TIB, and TLB tasks. This can be accomplished by using T4S or T24S tasks to transmit and R4S to receive the user's data. One should be aware, that the receive level and timing measurement circuits need to see a reasonably 'random' distribution of all four possible symbols in the received signal to operate correctly. Accordingly, binary data may benefit from scrambling before transmission if it is not reasonably 'random' to start with. 4.5.2.13 RSID: Read Station ID This task causes the modem to read in and decode the following 23 symbols as Station ID data followed by an 'S' symbol. It is similar to the last two parts of a SFP task except that it will not restart if the received CRC0 is incorrect. It would normally follow a SFS task. The three decoded bytes will be placed into the Data Block Buffer, and the CRCERR bit of the Status Register set to '1' if the received CRC0 is incorrect, otherwise it will be cleared to '0'. The SVAL bits of the Status Register will be updated and the BFREE, SRDY, and IRQ bits set to '1' to indicate that the PC may read the three received bytes from the Data Block buffer and write the next task to the modem's Command Register. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |