| поискавой системы для электроныых деталей |
|
RM0312 датащи(PDF) 259 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
RM0312 датащи(HTML) 259 Page - STMicroelectronics |
|
259 / 275 page ![]() DocID022352 Rev 3 259/275 RM0312 ProxSense™ (PXS) 273 22.9.2 ProxSense Control Register 2 (PXS_CR2) Address offset: 0x01 Reset value: 0x00 7654321 0 EOCITEN FCCITEN NOISEDETEN Reserved RXGROUP RXCOUPLING SYNCEN SYNCEDGE rw rw rw rw rw rw rw Bit 7 EOCITEN: End of conversion interrupt enable 0: End of conversion interrupt disabled 1: End of conversion interrupt enabled When enabled, an interrupt occurs when EOCF = 1, i.e., once all the conversions on the receivers have been completed. EOCF must be cleared during the interrupt service routine. Bit 6 FCCITEN: First conversion completion interrupt enable 0: First conversion completion interrupt disabled 1: First conversion completion interrupt enabled When enabled, an interrupt occurs when FCCF = 1, i.e., a first conversion is completed on one of the enabled receivers. Subsequent conversion completions on other channels do not trigger an interrupt, even if FCCF was previously cleared. Software can determine which channels have completed their conversions by reading the PXS_RXSR register. Bit 5 NOISEDETEN: Noise detection enable 0: RF Noise detection disabled 1: RF Noise detection enabled When NOISEDETEN = 1, the RF noise detection circuit is enabled. An antenna should be connected to the PXS_RFIN pin to detect RF noise properly. NOISEDETF in PXS_ISR indicates if noise was detected during a conversion. Note: This bit can be modified only when PXSEN = 0. Bit 4 Reserved Bit 3 RXGROUP: Rx group selection 0: Rx ‘A’ group (RX0A to RX9A) is active 1: Rx ‘B’ group (RX0B to RX9B) is active Note: When RXGROUP = 0, the Rx ‘B’ group is in the inactive state (as specified by PXS_RXINSR), and vice-versa. Note: This bit can be modified only when CIPF = 0. Bit 2 RXCOUPLING: Reduce coupling between receiver lines 0: The charge transfer cycle stops on a Rx line when its corresponding Cs has reached the threshold voltage (VTHR). 1: Each Rx which is activated (RXENn = 1) continues to toggle until all of the activated Rx channels have reached the threshold voltage (VTHR) or a timeout occurs. For applications where the Rx lines have significant coupling between each other, it may be beneficial to set this bit so that the parasitic coupling on a given Rx line does not increase after a neighboring Rx channel has reached the threshold voltage. Resetting this bit to 0 can reduce power consumption since some Rx lines would likely toggle for shorter periods of time. Note: This bit can be modified only when CIPF = 0. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |