41 / 105 page ![]() AN3985 ISO/IEC 15693 layer Doc ID 022255 Rev 2 41/105 ISO15693_Read_Multiple_Block function This function sends, through the CR95HF, a read multiple block command to the contactless tag in the field. Note: The data received is stored into the internal EEPROM of the MCU. ISO15693_Write_Multiple_Block function This function sends, through the CR95HF, a write multiple block command to the contactless tag in the field or to a unique contactless tag designated by its UID. Note: Data to send to the contactless tag is retrieved from the internal MCU EEPROM. Table 57. ISO15693_Read_Multiple_Block function description Prototype u8 ISO15693_Read_Multiple_Block(ISO15693_Tag* MyTag, const u8 Request_flags, const u8* Tag_UID, const u8 First_Block_number, const u8 Number_of_Blocks) Input parameter Request_flags: Specifies the actions to be performed by the contactless tag and whether corresponding fields are present or not (1). Tag_UID: pointer on the UID (optional) First_Block_number: address of the first block to read Number_of_Blocks: number of blocks to read 1. The Address flag indicates if Tag_UID field will be added to the command (addressed mode). Output parameter MyTag: pointer on the structure that contains the tag response Return parameter ISO15693_ERROR_CODE: The command failed. ISO15693_ERROR_PARAMETERS_REQUEST_FLAGS: There is an error within the request flags parameters. ISO15693_SUCCESS_CODE: The contactless tag answered the command. Table 58. ISO15693_Write_Multiple_Block function description Prototype u8 ISO15693_Write_Multiple_Block(ISO15693_Tag* MyTag, const u8 Request_flags, const u8* Tag_UID, const u8 First_Block_number, const u8 Number_of_Blocks,const u8 Block_Length) Input parameter Request_flags: Specifies the actions to be performed by the contactless tag and whether corresponding fields are present or not (1). Tag_UID: pointer on the UID (optional) First_Block_number: address of the first block to read Number_of_Blocks: number of blocks to read Block_Length: number of bytes in a block 1. The Address flag indicates if Tag_UID field will be added to the command (addressed mode). Output parameter MyTag: pointer on the structure that contains the tag response Return parameter ISO15693_ERROR_CODE: The command failed. ISO15693_ERROR_PARAMETERS_REQUEST_FLAGS: There is an error within the request flags parameters. ISO15693_SUCCESS_CODE: The contactless tag answered the command. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |