| поискавой системы для электроныых деталей |
|
AN3985 датащи(PDF) 78 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
AN3985 датащи(HTML) 78 Page - STMicroelectronics |
|
78 / 105 page ![]() M24LRxx layer AN3985 78/105 Doc ID 022255 Rev 2 M24LRxx_Present_Sector_Password function This function sends, through the CR95HF, a present sector password command to a contactless tag in the field. M24LRxx_Fast_Read_Single_Block function This function sends, through the CR95HF, a fast read single block command to a contactless tag in the field. The datarate of the response is multiplied by 2 (52 kbit/s in this case) Table 132. M24LRxx_Present_Sector_Password function description Prototype u8 M24LRxx_Present_Sector_Password(ISO15693_Tag* MyTag, const u8 Request_flags, const u8* Tag_UID,const u8 Password_Number ,const u8* Password); Input parameter Request_flags: Specifies the actions to be performed by the contactless tag and whether corresponding fields are present or not. (1) Tag_UID: pointer on the UID (optional) Password_Number: number identifying the password (between 1 and 3) Password: password to compare 1. The Address flag indicates if Tag_UID field will be added to the command (addressed mode). Output parameter MyTag: pointer on the structure that contains the tag response Return parameter M24LRxx_ERROR_CODE: The command failed. M24LRxx_ERROR_PARAMETERS_REQUEST_FLAGS: The inventory flag is set. M24LRxx_SUCCESS_CODE: Tag answered the command. Table 133. M24LRxx_Fast_Read_Single_Block function description Prototype u8 M24LRxx_Fast_Read_Single_Block(ISO15693_Tag* MyTag, const u8 Request_flags, const u8* Tag_UID, const u16 Block_number); Input parameter Request_flags: Specifies the actions to be performed by the contactless tag and whether corresponding fields are present or not. (1) (2) Tag_UID: pointer on the UID (optional) Block_number: address of the block to read (3) 1. The Address flag indicates if Tag_UID field will be added to the command (addressed mode). 2. If the memory size is more than 8 kbit, the protocol extension flag of request flags should be set. 3. If the memory size is more than 8 kbit, the block number is on two bytes. Output parameter MyTag: pointer on the structure that contains the tag response Return parameter M24LRxx_ERROR_CODE: The command failed. M24LRxx_ERROR_PARAMETERS_REQUEST_FLAGS: The inventory flag is set. M24LRxx_SUCCESS_CODE: The tag answered the command. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |