94 / 105 page ![]() Application example AN3985 94/105 Doc ID 022255 Rev 2 Figure 12. Halt CR95HF Timer mode flowchart 8.1.9 Communication test While waiting for an answer from the CR95HF, a timer is launched and the polling procedure is active during a limited period. If, at the end of this period, no answer is ready, the STM8L assumes that no answer will come and it increments a global counter called communication_watchdog. At the end of the secondary loop, this counter is checked and compared with a maximum value of tolerance. If it overtakes this value, a procedure is launched in order to resume the communication possibly lost. MS19968V1 Start of CR95HF Timer Mode End of Wait for interrupt mode Turn CR95HF in Idle mode CR95HF timeout = 5s ? No No Yes CR95HF Detect a tag ? No Yes Tag detected ? Yes Turn STM8L in halt mode Wake Up CR95HF Wake Up STM8L Check Wake up cause |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|