| поискавой системы для электроныых деталей |
|
ADF4112BCPZ датащи(PDF) 20 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADF4112BCPZ датащи(HTML) 20 Page - Analog Devices |
|
20 / 28 page ![]() ADF4110/ADF4111/ADF4112/ADF4113 Data Sheet Rev. F | Page 20 of 28 Note that there is an enable feature on the timer counter. It is enabled when Fastlock Mode 2 is chosen by setting the fastlock mode bit (DB10) in the function latch to 1. Charge Pump Currents CPI3, CPI2, and CPI1 program Current Setting 1 for the charge pump. CPI6, CPI5, and CPI4 program Current Setting 2 for the charge pump. The truth table is given in Table 10. Prescaler Value P2 and P1 in the function latch set the prescaler values. The prescaler value should be chosen so that the prescaler output frequency is always less than or equal to 200 MHz. Thus, with an RF frequency of 2 GHz, a prescaler value of 16/17 is valid but a value of 8/9 is not. PD Polarity This bit sets the phase detector polarity bit. See Table 10. CP Three-State This bit controls the CP output pin. With the bit set high, the CP output is put into three-state. With the bit set low, the CP output is enabled. INITIALIZATION LATCH When C2, C1 = 1, 1, the initialization latch is programmed. This is essentially the same as the function latch (programmed when C2, C1 = 1, 0). However, when the initialization latch is programmed, an addi- tional internal reset pulse is applied to the R and AB counters. This pulse ensures that the AB counter is at load point when the AB counter data is latched, and the device begins counting in close phase alignment. If the latch is programmed for synchronous power-down (CE pin high; PD1 bit high; PD2 bit low), the internal pulse also triggers this power-down. The prescaler reference and the oscillator input buffer are unaffected by the internal reset pulse, so close phase alignment is maintained when counting resumes. When the first AB counter data is latched after initialization, the internal reset pulse is again activated. However, successive AB counter loads after this will not trigger the internal reset pulse. DEVICE PROGRAMMING AFTER INITIAL POWER-UP After initial power-up of the device, there are three ways to program the device. Initialization Latch Method Apply VDD. Program the initialization latch (11 in 2 LSBs of input word). Make sure the F1 bit is programmed to 0. Then, do an R load (00 in 2 LSBs). Then do an AB load (01 in 2 LSBs). When the initialization latch is loaded, the following occurs: 1. The function latch contents are loaded. 2. An internal pulse resets the R, A, B, and timeout counters to load state conditions and three-states the charge pump. Note that the prescaler band gap reference and the oscil- lator input buffer are unaffected by the internal reset pulse, allowing close phase alignment when counting resumes. 3. Latching the first AB counter data after the initialization word activates the same internal reset pulse. Successive AB loads do not trigger the internal reset pulse unless there is another initialization. CE Pin Method 1. Apply VDD. 2. Bring CE low to put the device into power-down. This is an asynchronous power-down in that it happens immediately. 3. Program the function latch (10). Program the R counter latch (00). Program the AB counter latch (01). 4. Bring CE high to take the device out of power-down. The R and AB counters now resume counting in close alignment. After CE goes high, a duration of 1 µs may be required for the prescaler band gap voltage and oscillator input buffer bias to reach steady state. CE can be used to power the device up and down in order to check for channel activity. The input register does not need to be reprogrammed each time the device is disabled and enabled as long as it has been programmed at least once after VDD was initially applied. Counter Reset Method 1. Apply VDD. 2. Do a function latch load (10 in 2 LSBs). As part of this, load 1 to the F1 bit. This enables the counter reset. 3. Do an R counter load (00 in 2 LSBs). Do an AB counter load (01 in 2 LSBs). Do a function latch load (10 in 2 LSBs). As part of this, load 0 to the F1 bit. This disables the counter reset. This sequence provides the same close alignment as the initiali- zation method. It offers direct control over the internal reset. Note that counter reset holds the counters at load point and three states the charge pump but does not trigger synchronous power-down. The counter reset method requires an extra function latch load compared to the initialization latch method. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |