| поискавой системы для электроныых деталей |
|
BMM150 датащи(PDF) 27 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
BMM150 датащи(HTML) 27 Page - List of Unclassifed Manufacturers |
|
27 / 56 page ![]() Datasheet BMM150 Geomagnetic Sensor Page 27 BST-BMM150-DS001-01 | Revision 1.0 | April 2013 Bosch Sensortec © Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany. Note: Specifications within this document are subject to change without notice. Register (0x4C) contains control bits for operation mode, output data rate and self-test. The two “Adv. ST” bits control the on-chip advanced self-test (see chapter 4.4.2 for details of the magnetometer advanced self-test). The three “Data rate” bits control the magnetometer output data rate according to below Table 17. The two “Opmode” bits control the operation mode according to below Table 18 (see chapter 4.2 for a detailed description of magnetometer power modes). Table 16: Operation mode, output data rate and self-test control register (0x4C) (0x4C) Bit Name Description Bit 7 Adv. ST <1> Advanced self-test control bit 1 Bit 6 Adv. ST <0> Advanced self-test control bit 0 Bit 5 Data rate <2> Data rate control bit 2 Bit 4 Data rate <1> Data rate control bit 1 Bit 3 Data rate <0> Data rate control bit 0 Bit 2 Opmode <1> Operation mode control bit 1 Bit 1 Opmode <0> Operation mode control bit 0 Bit 0 Self Test Normal self-test control bit Three “Data rate” bits control the output data rate (ODR) of the BMM150 magnetometer part: Table 17: Output data rate (ODR) setting (0x4C) (0x4C) Data rate <2:0> Magnetometer output data rate (ODR) [Hz] 000b 10 (default) 001b 2 010b 6 011b 8 100b 15 101b 20 110b 25 111b 30 Two “Opmode” bits control the operation mode of the BMM150 magnetometer part: Table 18: Operation mode setting (0x4C) (0x4C) Opmode <1:0> Magnetometer operation mode6 00b Normal mode 01b Forced mode 10b Reserved, do not use 11b Sleep Mode 6 See chapter 4.2 for a detailed description of magnetometer power modes. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |