16 / 52 page ![]() 16 AT45DB321D [DATASHEET] 3597T–DFLASH–11/2013 8.1.2 Reading the Sector Lockdown Register The sector lockdown register can be read to determine which sectors in the memory array are permanently locked down. To read the sector lockdown register, the CS pin must first be asserted. Once the CS pin has been asserted, an opcode of 35H and three dummy bytes must be clocked into the device via the SI pin. After the last bit of the opcode and dummy bytes has been clocked in, the data for the content of the sector lockdown register will be clocked out on the SO pin. The first byte corresponds to sector 0 (0a, 0b) the second byte corresponds to sector 1, and the last byte (byte 16) corresponds to sector 15. After the last byte of the sector lockdown register has been read, additional pulses on the SCK pin will simply result in undefined data being output on the SO pin. Deasserting the CS pin will terminate the read sector lockdown register operation and put the SO pin into a high-impedance state. Table 8-4 details the values read from the sector lockdown register. Table 8-4. Sector Lockdown Register Command Byte 1 Byte 2 Byte 3 Byte 4 Note: xx = Dummy byte. Figure 8-2. Read Sector Lockdown Register 8.2 Security Register The device contains a specialized security register that can be used for purposes such as unique device serialization or locked key storage. The register is comprised of a total of 128 bytes that are divided into two portions. The first 64 bytes (byte locations 0 through 63) of the security register are allocated as a one-time user programmable space. Once these 64 bytes have been programmed, they cannot be reprogrammed. The remaining 64 bytes of the register (byte locations 64 through 127) are factory programmed by Adesto, and contain a unique value for each device. The factory programmed data are fixed and cannot be changed. Table 8-5. Security Register Security Register Byte Number 0 1 · · · 62 63 64 65 · · · 126 127 Read sector lockdown register 35H xxH xxH xxH Opcode X X X Data byte n Data byte n + 1 CS Data byte n + 63 SI SO Each transition represents 8 bits Data type One-time user programmable Adesto factory programmed |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |