| поискавой системы для электроныых деталей |
|
LTC1289BCSW датащи(PDF) 25 Page - Linear Technology |
|
|
|||||||||||||||||||||||||||||
LTC1289BCSW датащи(HTML) 25 Page - Linear Technology |
|
25 / 28 page ![]() 25 LTC1289 1289fb S APPLICATI TYPICAL Power Shutdown For battery-powered applications it is desirable to keep power dissipation at a minimum. The LTC1289 can be powered down when not in use reducing the supply current from a nominal value of 1mA to typically 1 µA (with ACLK turned off). See the Curve for Supply Current (Power Shutdown) vs ACLK if ACLK cannot be turned off when the LTC1289 is powered down. In this case the supply current is proportional to the ACLK frequency and is independent of temperature until it reaches the magnitude of the supply current attained with ACLK turned off. As an example of how to use this feature let’s add this to the previous application, SNEAK-A-BIT. After the CHK SIGN subroutine call insert the following: • • JSR CHK SIGN Determines which reading has valid data, converts to 2’s complement and stores in RAM JSR SHUTDOWN LTC1289 power shutdown routine The actual subroutine is: SHUTDOWN: LDA #$3D Load DIN word for LTC1289 into ACC JSR TRANSFER Read LTC1289 routine RTS Return To place the device in power shutdown the word length bits are set to WL1 = 0 and WL0 = 1. The LTC1289 is powered up on the next request for conversion and it's ready to digitize an input signal immediately. Power Shutdown Timing Considerations After power shutdown has been requested, the LTC1289 is powered up on the next request for a conversion. This request can be initiated either by bringing CS low or by starting the next cycle of SCLKs if CS is kept low (see Figures 3 and 4). When the SCLK frequency is much slower than the ACLK frequency a situation can arise where the LTC1289 could power down and then prema- turely power back up. Power shutdown begins at the negative going edge of the 10th SCLK once it has been requested. A dummy conversion is executed and the LTC1289 waits for the next request for conversion. If the SCLKs have not finished once the LTC1289 has finished its dummy conversion, it will recognize the next remaining SCLKs as a request to start a conversion and power up the LTC1289 (see Figure 23). To prevent this, bring either CS high at the 19th SCLK (Figure 24) or clock out only 10 SCLKs (Figure 25) when power shutdown is requested. Figure 23. Power Shutdown Timing Problem Figure 24. Power Shutdown Timing 110 SCLK CS POWER SHUTDOWN STARTS DUMMY CONVERSION FINISHES AFTER 52 ACLK PERIODS POWER UP LTC1289 TAF23 110 SCLK CS POWER SHUTDOWN STARTS DUMMY CONVERSION FINISHES AFTER 52 ACLK PERIODS POWER UP LTC1289 TAF24 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |