| поискавой системы для электроныых деталей |
|
TCS3772 датащи(PDF) 18 Page - ams AG |
|
|
|||||||||||||||||||||||||||||
TCS3772 датащи(HTML) 18 Page - ams AG |
|
18 / 33 page ![]() TCS3772 COLOR LIGHT-TO-DIGITAL CONVERTER with PROXIMITY SENSING TAOS145B − SEPTEMBER 2012 17 The LUMENOLOGY r Company r r Copyright E 2012, TAOS Inc. www.taosinc.com Register Set The TCS3772 is controlled and monitored by data registers and a command register accessed through the serial interface. These registers provide for a variety of control functions and can be read to determine results of the ADC conversions. The register set is summarized in Table 3. Table 3. Register Address ADDRESS RESISTER NAME R/W REGISTER FUNCTION RESET VALUE −− COMMAND W Specifies register address 0x00 0x00 ENABLE R/W Enables states and interrupts 0x00 0x01 ATIME R/W RGBC time 0xFF 0x02 PTIME R/W Proximity time 0xFF 0x03 WTIME R/W Wait time 0xFF 0x04 AILTL R/W Clear interrupt low threshold low byte 0x00 0x05 AILTH R/W Clear interrupt low threshold high byte 0x00 0x06 AIHTL R/W Clear interrupt high threshold low byte 0x00 0x07 AIHTH R/W Clear interrupt high threshold high byte 0x00 0x08 PILTL R/W Proximity interrupt low threshold low byte 0x00 0x09 PILTH R/W Proximity interrupt low threshold high byte 0x00 0x0A PIHTL R/W Proximity interrupt high threshold low byte 0x00 0x0B PIHTH R/W Proximity interrupt high threshold high byte 0x00 0x0C PERS R/W Interrupt persistence filters 0x00 0x0D CONFIG R/W Configuration 0x00 0x0E PPULSE R/W Proximity pulse count 0x00 0x0F CONTROL R/W Gain control register 0x00 0x12 ID R Device ID ID 0x13 STATUS R Device status 0x00 0x14 CDATA R Clear ADC data low byte 0x00 0x15 CDATAH R Clear ADC data high byte 0x00 0x16 RDATA R Red ADC data low byte 0x00 0x17 RDATAH R Red ADC data high byte 0x00 0x18 GDATA R Green ADC data low byte 0x00 0x19 GDATAH R Green ADC data high byte 0x00 0x1A BDATA R Blue ADC data low byte 0x00 0x1B BDATAH R Blue ADC data high byte 0x00 0x1C PDATA R Proximity ADC data low byte 0x00 0x1D PDATAH R Proximity ADC data high byte 0x00 The mechanics of accessing a specific register depends on the specific protocol used. See the section on I2C protocols on the previous pages. In general, the COMMAND register is written first to specify the specific control/status register for following read/write operations. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |