| поискавой системы для электроныых деталей |
|
AS8525 датащи(PDF) 15 Page - ams AG |
|
|
|||||||||||||||||||||||||||||
AS8525 датащи(HTML) 15 Page - ams AG |
|
15 / 38 page ![]() www.ams.com/AS8525 Revision 2.3 14 - 37 AS8525 Datasheet - Electrical Character i s t ics 6.2.8 Other Modules Table 14. Other Modules Symbol Parameter Conditions Min Typ Max Units Vuvr_off VCC under-voltage threshold off (default) Rising edge of VCC 2.55 2.95 V Vuvr_on VCC under-voltage threshold on (default) Falling edge of VCC 2.3 2.7 V Vuvr1_off VCC under voltage threshold off (factory option) Rising edge of VCC 3.0 3.4 V Vuvr1_on VCC under voltage threshold on (factory option) Falling edge of VCC 2.75 3.15 V Vuvr2_off VCC under voltage threshold off (factory option) Rising edge of VCC 3.5 3.9 V Vuvr2_on VCC under voltage threshold on (factory option) Falling edge of VCC 3.25 3.65 V Vuvr3_off VCC under-voltage threshold off (factory option) Rising edge of VCC 4.0 4.4 V Vuvr3_on VCC under voltage threshold on (factory option) Falling edge of VCC 3.75 4.15 V Vhyst_vcc Hysteresis of under-voltage threshold on/ off VCC For all OTP options 0.1 0.25 0.4 V trr Glitch filter on VCC under-voltage detection See Reset Functionality (page 18) 4µs Vsuvr_off VSUP under-voltage threshold off Rising edge of VSUP 5.1 V Vsuvr_on VSUP under-voltage threshold on Falling edge of VSUP 3.8 V WD_TCL WWD non-service time (factory option) RESET will be generated 0-75 0-100 0-125 ms WD_TSV WWD Service time (factory option) RESET will not be generated 75-150 100-200 125-250 ms WD_TCL1 WWD non-service time (factory option) RESET will be generated 0-60 0-80 0-100 ms WD_TSV1 WWD Service time (factory option) RESET will not be generated 60-120 80-160 100-200 ms WD_TCL2 WWD non-service time (factory option) RESET will be generated 0-45 0-60 0-75 ms WD_TSV2 WWD Service time (factory option) RESET will not be generated 45-90 60-120 75-150 ms WD_TCL3 WWD non-service time (factory option) RESET will be generated 0-150 0-200 0-250 ms WD_TSV3 WWD Service time (factory option) RESET will not be generated 150-300 200-400 250-500 ms WD_TCL4 WWD non-service time (factory option) RESET will be generated 0-120 0-160 0-200 ms WD_TSV4 WWD Service time (factory option) RESET will not be generated 120-240 160-320 200-400 ms WD_TCL5 WWD non-service time (factory option) RESET will be generated 0-90 0-120 0-150 ms WD_TSV5 WWD Service time (factory option) RESET will not be generated 90-180 120-240 150-300 ms WD_T TWD service time T is configured through SPI 0.75*T T 1.25*T s tRes Reset period Min = -25% and Max = +50% 6 8 12 ms Tshd Temporary shutdown reset active time 0.1 1 s |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |