17 / 81 page ![]() www.austriamicrosystems.com/AS3675 1v3 16 - 80 AS3675 Datasheet - D e ta i l e d D e s c r i p t i o n 8.3 Charge Pump The Charge Pump uses two external flying capacitors C3, C4 to generate output voltages higher than the battery volt- age. There are three different operating modes of the charge pump itself: 1:1 Bypass Mode - Battery input and output are connected by a low-impedance switch - battery current = output current. 1:1.5 Mode - The output voltage is up to 1.5 times the battery voltage (without load), but is limited to VCPOUTmax all the time - battery current = 1.5 times output current. 1:2 Mode - The output voltage is up to 2 times the battery voltage (without load), but is limited to VCPOUTmax all the time - battery current = 2 times output current As the battery voltage decreases, the Charge Pump must be switched from 1:1 mode to 1:1.5 mode and eventually in 1:2 mode in order to provide enough supply for the current sinks. Depending on the actual current the mode with best overall efficiency can be automatically or manually selected: Examples: Battery voltage = 3.7V, LED dropout voltage = 3.5V. The 1:1 mode will be selected and there is 200mV drop on the current sink and on the Charge Pump switch. Efficiency 95%. Battery voltage = 3.5V, LED dropout voltage = 3.5V. The 1:1.5 mode will be selected and there is 1.5V drop on the current sink and 250mV on the Charge Pump. Efficiency 66%. Battery voltage = 3.8V, LED dropout voltage = 4.5V (Camera Flash). The 1:2 mode can be selected and there is 600mV drop on the current sink and 2.5V on the Charge Pump. Efficiency 60%. The efficiency is dependent on the LED forward voltage given by: Eff=(V_LED*Iout)/(Uin*Iin) (EQ 4) The charge pump mode switching can be done manually or automatically with the following possible software settings: Automatic up all modes allowed (1:1, 1:1.5, 1:2) - Start with 1:1 mode - Switch up automatically 1:1 to 1:1.5 to 1:2 Automatic up, but only 1:1 and 1:1.5 allowed - Start with 1:1 mode - Switch up automatically only from 1:1 to 1:1.5 mode; 1:2 mode is not used Manual - Set modes 1:1, 1:1.5, 1:2 by software 3 Step up_lowcur 1R/W Step Up DC/DC Converter coil current limit 0 Normal current limit 1 Current limit reduced by approx. 33% 7 step_up_fb_auto 0R/W 0 step_up_fb select the feedback of the DCDC converter 1 The feedback is automatically chosen within the current sinks CURR1, CURR2 and CURR6 (never DCDC_FB). Only those are used for this selection, which are enabled (currX_mode must not be 00) and not connected to the charge pump (currX_on_cp must be 0). Table 12. DCDC control2 Register Addr: 22h DCDC control2 This register controls the Step Up DC/DC Converter and low-voltage current sinks CURR3x. Bit Bit Name Default Access Description |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |