| поискавой системы для электроныых деталей |
|
AM79C960KC датащи(PDF) 42 Page - Advanced Micro Devices |
|
|
|||||||||||||||||||||||||||||
AM79C960KC датащи(HTML) 42 Page - Advanced Micro Devices |
|
42 / 127 page ![]() P R E L I M I N A R Y AMD 1-384 Am79C960 PLL Tracking After clock acquisition, the phase-locked clock is com- pared to the incoming transition at the bit cell center (BCC) and the resulting phase error is applied to a cor- rection circuit. This circuit ensures that the phase-locked clock remains locked on the received sig- nal. Individual bit cell phase corrections of the Voltage Controlled Oscillator (VCO) are limited to 10% of the phase difference between BCC and phase-locked clock. Hence, input data jitter is reduced in ISRDCLK by 10 to 1. Carrier Tracking and End of Message The carrier detection circuit monitors the DI ± inputs after IRXCRS is asserted for an end of message. IRXCRS de-asserts 1 to 2 bit times after the last positive transi- tion on the incoming message. This initiates the end of reception cycle. The time delay from the last rising edge of the message to IRXCRS deassert allows the last bit to be strobed by ISRDCLK and transferred to the controller section, but prevents any extra bit(s) at the end of message. Data Decoding The data receiver is a comparator with clocked output to minimize noise sensitivity to the DI ±/RXD± inputs. Input error is less than ± 35 mV to minimize sensitivity to input rise and fall time. ISRDCLK strobes the data receiver output at 1/4 bit time to determine the value of the Manchester bit, and clocks the data out on IRXDAT on the following ISRDCLK. The data receiver also gener- ates the signal used for phase detector comparison to the internal MENDEC voltage controlled oscillator (VCO). Jitter Tolerance Definition The MENDEC utilizes a clock capture circuit to align its internal data strobe with an incoming bit stream. The clock acquisition circuitry requires four valid bits with the values 1010b. Clock is phase-locked to the negative transition at the bit cell center of the second “0” in the pattern. Since data is strobed at 1/4 bit time, Manchester transi- tions which shift from their nominal placement through 1/4 bit time will result in improperly decoded data. With this as the criteria for an error, a definition of “Jitter Han- dling” is: The peak deviation approaching or crossing 1/4 bit cell position from nominal input transition, for which the MENDEC section will properly de- code data. Attachment Unit Interface (AUI) The AUI is the PLS (Physical Layer Signaling) to PMA (Physical Medium Attachment) interface which connects the DTE to a MAU. The differential interface provided by the PCnet-ISA controller is fully compliant with Section 7 of ISO 8802-3 (ANSI/IEEE 802.3). After the PCnet-ISA controller initiates a transmission, it will expect to see data “looped-back” on the DI ± pair (when the AUI port is selected). This will internally generate a “carrier sense”, indicating that the integrity of the data path to and from the MAU is intact, and that the MAU is operating correctly. This “carrier sense” signal must be asserted within sometime before end of trans- mission. If “carrier sense” does not become active in response to the data transmission, or becomes inactive before the end of transmission, the loss of carrier (LCAR) error bit will be set in the Transmit Descriptor Ring (TMD3, bit 11) after the packet has been transmitted. Differential Input Terminations The differential input for the Manchester data (DI ±) is externally terminated by two 40.2 Ω ±1% resistors and one optional common-mode bypass capacitor, as shown in the Differential Input Termination diagram below. The differential input impedance, ZIDF, and the common-mode input impedance, ZICM, are specified so that the Ethernet specification for cable termination im- pedance is met using standard 1% resistor terminators. If SIP devices are used, 39 Ω is the nearest usable equivalent value. The CI ± differential inputs are termi- nated in exactly the same way as the DI ± pair. PCnet-ISA DI+ DI- 40.2 Ω 40.2 Ω 0.01 µF to 0.1 µF AUI Isolation Transformer 16907B-9 Differential Input Termination Collision Detection A MAU detects the collision condition on the network and generates a differential signal at the CI ± inputs. This collision signal passes through an input stage which de- tects signal levels and pulse duration. When the signal is detected by the MENDEC it sets the ICLSN line HIGH. The condition continues for approximately 1.5 bit times after the last LOW-to-HIGH transition on CI ±. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |