| поискавой системы для электроныых деталей |
|
CPM2CS100C датащи(PDF) 4 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
CPM2CS100C датащи(HTML) 4 Page - Omron Electronics LLC |
|
4 / 5 page ![]() CPM2C-S1❑0C CPM2C-S1❑0C 4 For more information, contact an Omron representative at 1-800-55-OMRON s Communication Specifications Item Specifications Communications method CompoBus/S protocol Coding method Manchester coding method Connection method Multi-drop method and T-branch method (See note 1) Communications baud rate High-speed communications mode: 750 kbps Long-distance communications mode: 93.75 kbps (See note 2) Communications High-speed 0.5 ms. (No. of connected Slaves: 8 input, 8 output) cycle time communications 0.8 ms. (No. of connected Slaves: 16 input, 16 output) mode Long-distance 4.0 ms. (No. of connected Slaves: 8 input, 8 output) communications 6.0 ms. (No. of connected Slaves: 16 input, 16 output) mode Communications cable 2-conductor VCTF cable (0.75 x 2) 4-conductor VCTF cable (0.75 x 4) Special flat cable Communications 2-conductor High-speed communications mode distance VCTF cable Main line length: 100 m max. Branch line length: 3 m max. Total branch line length: 50 m max. Long-distance communications mode Main line length: 500 m max. Branch line length: 6 m max. Total branch line length: 120 m max. Flat cable or High-speed communications mode (see note 3) 4-conductor Main line length: 30 m max. VCTF cable Branch line length: 3 m max. Total branch line length: 30 m max. Long-distance communications mode (see note 4) Variable branch wiring (total cable length 200 m max.) Maximum number of connecting nodes 32 Error control checks Manchester code check, frame length check, and parity check Note: 1. An external terminator must be connected. Note: 2. Controlled by DM area setting (default setting: 750 kbps). Note: 3. When flat cable is used to connect fewer than 16 slaves, the main line can be up to 100 m long and the total branch line length can be up to 50 m. Note: 4. There are no limits on the branching format or main, branch, or total line lengths. The terminator must be connected to the point in the system farthest from the master. Dimensions CPM2C-S1s s s C |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |