3 / 5 page ![]() 3 For more information, contact an Omron representative at 1-800-55-OMRON CPM2C-S1❑0C CPM2C-S1❑0C s General and Performance Specifications (continued) Item Specifications Data Memory Read/Write 2,048 words (DM 0000 to DM 2047) The Error Log is contained in DM 2000 to DM 2021 Read-only 456 words (DM 6144 to DM 6599) PC Setup 56 words (DM 6600 to DM 6655) Basic interrupt functions Input interrupts 2 interrupts (shared by input interrupt counter mode and the quick-response inputs) Scheduled 1 interrupt interrupts High-speed counter High-speed 1 counter (20 kHz single-phase or 5 kHz two-phase) functions counter Counter interrupt 1 interrupt Input interrupts 2 interrupts (shared by input interrupt counter mode and the quick-response inputs) (counter mode) Count-up interrupt 2 interrupts (shared by input interrupt counter mode and the quick-response inputs) Quick-response inputs 2 inputs Minimum pulse input: 50 µs Shared by input interrupts and input interrupt counter mode Pulse outputs Either 2 points with no acceleration/deceleration, 10 Hz to 10 kHz each, and no direction control, 1 point with trapezoid acceleration/deceleration, 10 Hz to 10 kHz, and direction control, or 2 points with variable duty-ratio outputs Synchronized pulse control 1 point Input time constant Can be set for CPU Unit inputs and Expansion Unit input points (ON response time = OFF response time) (1, 2, 3, 5, 10, 20, 40, or 80 ms) Clock function Built-in RTC Communications Peripheral port: Supports Host Link, peripheral bus, no protocol, or Programming Console connections functions RS-232C port: Supports Host Link, no protocol, 1:1 Slave Unit Link, 1:1 Master Unit Link, or 1:1 NT Link connections Memory protection HR area, AR area, counter values, read/write DM area contents, and counter values maintained during power interruptions Memory backup Non-volatile memory, user programs, read-only DM area and PC setup are backed up Lithium battery (2-year) DM area, HR area, AR area and counter values are backed up Self-diagnostic functions CPU Unit failure (watchdog timer), memory failure, communications error, setting error, battery error, and I/O bus error Program checks No END instruction, programming errors (checked when operation is started) Connection tools Programming C200H-PRO27, CQM1-PRO01, CQM1H-PRO01 console SSS IBM PC/AT or compatible (SYSMAC Support Software V1.1) CPT Windows CX-P Windows |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |