| поискавой системы для электроныых деталей |
|
MPC8315 датащи(PDF) 32 Page - Freescale Semiconductor, Inc |
|
|
|||||||||||||||||||||||||||||
MPC8315 датащи(HTML) 32 Page - Freescale Semiconductor, Inc |
|
32 / 106 page ![]() MPC8315E PowerQUICC II Pro Processor Hardware Specifications, Rev. 2 32 Freescale Semiconductor Ethernet: Three-Speed Ethernet, MII Management 9.3.2 MII Management AC Electrical Specifications This table provides the MII management AC timing specifications. Input low current IIL NVDD = Max VIN = 0.5 V –600 — A Note: 1. The symbol VIN, in this case, represents the NVIN symbol referenced in Table 1 and Table 2. Table 31. MII Management AC Timing Specifications At recommended operating conditions with NVDD is 3.3 V ± 300 mv Parameter/Condition Symbol 1 Min Typ Max Unit Note MDC frequency fMDC —2.5 — MHz 2 MDC period tMDC — 400 — ns — MDC clock pulse width high tMDCH 32 — — ns — MDC to MDIO delay tMDKHDX 10 — 170 ns 3 MDIO to MDC setup time tMDDVKH 5— — ns — MDIO to MDC hold time tMDDXKH 0— — ns — MDC rise time tMDCR — — 10 ns — MDC fall time tMDHF — — 10 ns — Note: 1. The symbols used for timing specifications herein follow the pattern of t(first two letters of functional block)(signal)(state)(reference)(state) for inputs and t(first two letters of functional block)(reference)(state)(signal)(state) for outputs. For example, tMDKHDX symbolizes management data timing (MD) for the time tMDC from clock reference (K) high (H) until data outputs (D) are invalid (X) or data hold time. Also, tMDDVKH symbolizes management data timing (MD) with respect to the time data input signals (D) reach the valid state (V) relative to the tMDC clock reference (K) going to the high (H) state or setup time. For rise and fall times, the latter convention is used with the appropriate letter: R (rise) or F (fall). 2. This parameter is dependent on the csb_clk speed (that is, for a csb_clk of 133 MHz, the maximum frequency is 4.16 MHz and the minimum frequency is 0.593 MHz). 3. This parameter is dependent on the csb_clk speed (that is, for a csb_clk of 133 MHz, the delay is 60 ns). Table 30. MII Management DC Electrical Characteristics Powered at 3.3 V (continued) Parameter Symbol Conditions Min Max Unit |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |