ADMC200AP датащи(PDF) 7 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADMC200AP датащи(HTML) 7 Page - Analog Devices |
|
7 / 12 page ![]() ADMC200 REV. B –7– desired on-time and their values would be calculated as a ratio of the PWMTM register value. Note: Desired Pulse Density = (PWMCHx register)/( PWMTM register). The beginning of each PWM cycle is marked by the PWMSYNC signal. New values of PWMCHA, PWMCHB and PWMCHC must all be loaded into their respective registers at least four sys- tem clock cycles before the beginning of a new PWM cycle. All three registers must be updated for any of them to take effect. New PWM on/off times are calculated during these four clock cycles and therefore the PWMCHA, PWMCHB and PWMCHC registers must be loaded before this time. If this timing require- ment is not met, then the PWM outputs may be invalid during the next PWM cycle. PWM Example The following example uses a system clock speed of 10 MHz. The desired PWM master switching frequency is 8 kHz and the desired on-time for the timers A, B and C are 25%, 50% and 10% respectively. The values for the PWMCHA, PWMCHB, and PWMCHC registers must be calculated as ratios of the PWMTM register (1250 in this example). To achieve these duty cycles, load the PWMCHA register with 313 (1250 × 0.25), PWMCHB with 625 (1250 × 0.5) and PWMCHC with 125 (1250 × 0.1). Programmable Deadtime With perfectly complemented PWM drive signals and nonideal switching characteristics of the power devices, both transistors in a particular leg might be switched on at the same time, result- ing in either a power supply trip, inverter trip or device destruc- tion. In order to prevent this, a delay must be introduced between the complemented signal edges. For example, the ris- ing edge of AP occurs before the falling edge of A, and the fall- ing edge of the complemented A occurs after the rising edge of A. This capability is known as programmable deadtime. The ADMC200 programmable deadtime value is loaded into the 7-bit PWMDT register, in which the LSB is set to zero in- ternally, which means the deadtime value is always divisible by two. With a 10 MHz system clock, the 0–126 range of values in PWMDT yield a range of deadtime values from 0 µs to 12.6 µs in 200 ns steps. Figure 6 shows PWM timer A with a program- mable deadtime of PWMDT. PWMCHA - PWMDT A PWMTM AP PWMCHA + PWMDT Figure 6. Programmable Deadtime Example Pulse Deletion The pulse deletion feature prevents a pulse from being gener- ated when the user-specified duty cycle results in a pulse dura- tion shorter than the user-specified deletion value. The pulse deletion value is loaded into the 7-bit register PWMPD. When the user-specified on-time for a channel would result in a calcu- lated pulsewidth less than the value specified in the PWMPD register, then the PWM outputs for that channel would be set to full off (0%) and its prime to full on (100%). This is valid for A, AP, B, BP, C and CP. This feature would be used in an en- vironment where the inverter’s power transistors have a mini- mum switching time. If the user-specified duty cycle would result in a pulse duration shorter than the minimum switching time of the transistors, then pulse deletion should be used to prevent this occurrence. With a 10 MHz system clock, the 0– 127 range of values in PWMPD yield a range of deadtime values from 0 µs to 12.7 µs in 100 ns steps. External PWM Shutdown There is an external input pin (STOP) to the PWM timers that will disable all six outputs when it goes HIGH. When the STOP pin goes HIGH, the PWM timer outputs will all go HIGH within one system clock cycle. When the STOP pin goes LOW, the PWM timer outputs are re-enabled within one system clock cycle. If external PWM shutdown isn’t required, tie the STOP pin LOW. VECTOR TRANSFORMATION BLOCK OVERVIEW The Vector Transformation Block performs both Park and Clarke coordinate transformations to control a three-phase motor (Permanent Magnet Synchronous Motor or Induction Motor) via independent control of the decoupled rotor torque and flux currents. The Park and Clarke transformations combine to convert three-phase stator current signals into two orthogonal rotor referenced current signals Id and Iq. Id represents the flux or magnetic field current and Iq represents the torque generat- ing current. The Id and Iq current signals are used by the processor’s motor torque control algorithm to calculate the required direct Vd and quadrature Vq voltage components for the motor. The forward Park and Clarke transformations are used to convert the Vd and Vq voltage signals in the rotor reference frame to three phase voltage signals (U, V, W) in the stator reference frame. These are then scaled by the processor and written to the ADMC200’s PWM registers in order to drive the inverter. The figures below illustrate the Clarke and Park Trans- formations respectively. Iw Iu Iv Iy Ix 120 ° 120 ° 120 ° Three-Phase Equivalent Stator Currents Two-Phase Currents Figure 7. Reverse Clarke Transformation Iy Ix ρ Iq Id ROTOR REFERENCE FRAME AXIS 90 ° Rotating Stationary Reference Frame Reference Frame Figure 8. Reverse Park Transformation |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |