16 / 20 page ![]() ADF4116/ADF4117/ADF4118 –16– REV. 0 THE FUNCTION LATCH With C2, C1 set to 1, 0, the on-chip function latch will be pro- grammed. Table VI shows the input data format for programming the Function Latch. Counter Reset DB2 (F1) is the counter reset bit. When this is “1,” the R counter and the A, B counters are reset. For normal operation this bit should be “0.” Upon powering up, the F1 bit needs to be disabled, the N counter resumes counting in “close” alignment with the R counter. (The maximum error is one prescaler cycle.) Power-Down DB3 (PD1) and DB19 (PD2) on the ADF4116 family, provide programmable power-down modes. They are enabled by the CE pin. When the CE pin is low, the device is immediately disabled regardless of the states of PD2, PD1. In the programmed asynchronous power-down, the device pow- ers down immediately after latching a “1” into bit PD1, with the condition that PD2 has been loaded with a “0.” In the programmed synchronous power-down, the device power down is gated by the charge pump to prevent unwanted fre- quency jumps. Once the power-down is enabled by writing a “1” into bit PD1 (on condition that a “1” has also been loaded to PD2), then the device will go into power-down after the first successive charge pump event. When a power down is activated (either synchronous or asynchro- nous mode including CE-pin-activated power down), the following events occur: All active dc current paths are removed. The R, N and timeout counters are forced to their load state conditions. The charge pump is forced into three-state mode. The digital clock detect circuitry is reset. The RFIN input is debiased. The oscillator input buffer circuitry is disabled. The input register remains active and capable of loading and latching data. MUXOUT Control The on-chip multiplexer is controlled by M3, M2, M1 on the ADF4116 family. Table VI shows the truth table. Phase Detector Polarity DB7 (F2) of the function latch sets the Phase Detector Polarity. When the VCO characteristics are positive this should be set to “1.” When they are negative it should be set to “0.” Charge Pump Three-State This bit puts the charge pump into three-state mode when pro- grammed to a “1.” It should be set to “0” for normal operation. Fastlock Enable Bit DB9 of the Function Latch is the Fastlock Enable Bit. Only when this is “1” is Fastlock enabled. Fastlock Mode Bit DB11 of the Function Latch is the Fastlock Mode bit. When Fastlock is enabled, this bit determines which Fastlock Mode is used. If the Fastlock Mode bit is “0” then Fastlock Mode 1 is selected and if the Fastlock Mode bit is “1,” then Fastlock Mode 2 is selected. If Fastlock is not enabled (DB9 = “0”), then DB11 (ADF4116) determines the state of the FLO output. FLO state will be the same as that programmed to DB11. Fastlock Mode 1 In the ADF4116 family, the output level of FLO is programmed to a low state and the charge pump current is switched to the high value (1 mA). FLO is used to switch a resistor in the loop filter and ensure stability while in Fastlock by altering the loop bandwidth. The device enters Fastlock by having a “1” written to the CP Gain bit in the N register. The device exits Fastlock by having a “0” written to the CP Gain bit in the N register. Fastlock Mode 2 In the ADF4116 family, the output level of FLO is programmed to a low state and the charge pump current is switched to the high value (1 mA). FLO is used to switch a resistor in the loop filter and ensure stability while in Fastlock by altering the loop bandwidth. The device enters Fastlock by having a “1” written to the CP Gain bit in the N register. The device exits Fastlock under the control of the Timer Counter. After the timeout period deter- mined by the value in TC4–TC1, the CP Gain bit in the N register is automatically reset to “0” and the device reverts to normal mode instead of Fastlock. Timer Counter Control In the ADF4116 family, the user has the option of switching between two charge pump current values to speed up locking to a new frequency. When using the Fastlock feature with the ADF4116 family, the normal sequence of events is as follows: The user must make sure that Fastlock is enabled. Set DB9 of the ADF4116 family to “1.” The user must also choose which Fastlock Mode to use. As discussed in the previous section, Fastlock Mode 2 uses the values in the Timer Counter to determine the timeout period before reverting to normal mode operation after Fastlock. Fastlock Mode 2 is chosen by setting DB11 of the ADF4116 family to “1.” The user must also decide how long they want the high current (1 mA) to stay active before reverting to low current (250 µA). This is controlled by the Timer Counter Control Bits DB14 to DB11 (TC4–TC1) in the Function Latch. The truth table is given in Table VI. Now, when the user wishes to program a new output frequency, they can simply program the A, B counter latch with new values for A and B. At the same time they can set the CP Gain bit to a “1,” which sets the charge pump 1 mA for a period of time deter- mined by TC4–TC1. When this time is up, the charge pump current reverts to 250 µA. At the same time the CP Gain Bit in the A, B Counter latch is reset to 0 and is now ready for the next time that the user wishes to change the frequency again. |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |