| поискавой системы для электроныых деталей |
|
AD9518-2 датащи(PDF) 31 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD9518-2 датащи(HTML) 31 Page - Analog Devices |
|
31 / 64 page ![]() Data Sheet AD9518-2 Rev. C | Page 31 of 64 Holdover The AD9518 PLL has a holdover function, which is implemented by putting the charge pump into a state of high impedance. This is useful when the PLL reference clock is lost. Holdover mode allows the VCO to maintain a relatively constant frequency even though there is no reference clock. Without this function, the charge pump is placed into a constant pump-up or pump- down state, resulting in a massive VCO frequency shift. Because the charge pump is placed in a high impedance state, any leakage that occurs at the charge pump output or the VCO tuning node causes a drift of the VCO frequency. This can be mitigated by using a loop filter that contains a large capacitive component because this drift is limited by the current leakage induced slew rate (ILEAK/C) of the VCO control voltage. For most applications, the frequency accuracy is sufficient for 3 sec to 5 sec. Both a manual holdover, using the SYNC pin, and an automatic holdover mode are provided. To use either function, the holdover function must be enabled (Register 0x01D[0] and Register 0x01D[2]). Note that the VCO cannot be calibrated with the holdover enabled because the holdover resets the N divider during calibration, which prevents proper calibration. Disable holdover before issuing a VCO calibration. Manual Holdover Mode A manual holdover mode can be enabled that allows the user to place the charge pump into a high impedance state when the SYNC pin is asserted low. This operation is edge sensitive, not level sensitive. The charge pump enters a high impedance state immediately. To take the charge pump out of a high impedance state, take the SYNC pin high. The charge pump then leaves high impedance state synchronously with the next PFD rising edge from the reference clock. This prevents extraneous charge pump events from occurring during the time between SYNC going high and the next PFD event. This also means that the charge pump stays in a high impedance state as long as there is no reference clock present. The B-counter (in the N divider) is reset synchronously with the charge pump leaving the high impedance state on the reference path PFD event. This helps align the edges out of the R and N dividers for faster settling of the PLL. Because the prescaler is not reset, this feature works best when the B and R numbers are close because this results in a smaller phase difference for the loop to settle out. When using this mode, set the channel dividers to ignore the SYNC pin (at least after an initial SYNC event). If the dividers are not set to ignore the SYNC pin, the distribution outputs turn off each time SYNC is taken low to put the part into holdover. Automatic/Internal Holdover Mode When enabled, this function automatically puts the charge pump into a high impedance state when the loop loses lock. The assumption is that the only reason the loop loses lock is due to the PLL losing the reference clock; therefore, the holdover function puts the charge pump into a high impedance state to maintain the VCO frequency as close as possible to the original frequency before the reference clock disappears. See Figure 38 for a flow chart of the automatic/internal holdover function operation. NO NO NO NO YES YES YES YES YES PLL ENABLED DLD == LOW WAS LD PIN == HIGH WHEN DLD WENT LOW? HIGH IMPEDANCE CHARGE PUMP REFERENCE EDGE AT PFD? RELEASE CHARGE PUMP HIGH IMPEDANCE DLD == HIGH LOOP OUT OF LOCK. DIGITAL LOCK DETECT SIGNAL GOES LOW WHEN THE LOOP LEAVES LOCK AS DETERMINED BY THE PHASE DIFFERENCE AT THE INPUT OF THE PFD. CHARGE PUMP IS MADE HIGH IMPEDANCE. PLL COUNTERS CONTINUE OPERATING NORMALLY. CHARGE PUMP REMAINS HIGH IMPEDANCE UNTIL THE REFERENCE HAS RETURNED. TAKE CHARGE PUMP OUT OF HIGH IMPEDANCE. PLL CAN NOW RESETTLE. WAIT FOR DLD TO GO HIGH. THIS TAKES 5 TO 255 CYCLES (PROGRAMMING OF THE DLD DELAY COUNTER) WITH THE REFERENCE AND FEEDBACK CLOCKS INSIDE THE LOCK WINDOW AT THE PFD. THIS ENSURES THAT THE HOLDOVER FUNCTION WAITS FOR THE PLL TO SETTLE AND LOCK BEFORE THE HOLDOVER FUNCTION CAN BE RETRIGGERED. YES ANALOG LOCK DETECT PIN INDICATES LOCK WAS PREVIOUSLY ACHIEVED. (0x01D[3] = 1: USE LD PIN VOLTAGE WITH HOLDOVER. 0x01D[3] = 0: IGNORE LD PIN VOLTAGE, TREAT LD PIN AS ALWAYS HIGH.) Figure 38. Flow Chart of Automatic/Internal Holdover Mode |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |