| поискавой системы для электроныых деталей |
|
AD9518-2 датащи(PDF) 47 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD9518-2 датащи(HTML) 47 Page - Analog Devices |
|
47 / 64 page ![]() Data Sheet AD9518-2 Rev. C | Page 47 of 64 Reg. Addr. (Hex) Parameter Bit 7 (MSB) Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 (LSB) Default Value (Hex) System 0x230 Power-down and sync Reserved Power down sync Power down distribution reference Soft sync 0x00 0x231 Blank Reserved 0x00 Update All Registers 0x232 Update all registers Blank Update all registers (self-clearing bit) 0x00 CONTROL REGISTER MAP DESCRIPTIONS Table 43 through Table 49 provide a detailed description of each of the control register functions. The registers are listed by hexadecimal address. A range of bits (for example, from Bit 5 through Bit 2) is indicated using a colon and brackets, as follows: [5:2]. Table 43. Serial Port Configuration and Part ID Reg. Addr (Hex) Bits Name Description 0x000 [7:4] Mirrored, Bits[3:0] Bits[7:4] should always mirror Bits[3:0] such that it does not matter whether the part is in MSB or LSB first mode (see Bit 1, Register 0x000). The user should set the bits as follows: Bit 7 = Bit 0. Bit 6 = Bit 1. Bit 5 = Bit 2. Bit 4 = Bit 3. 3 Long instruction Short/long instruction mode. This part uses long instruction mode only, so this bit should always be set to 1b. 0: 8-bit instruction (short). 1: 16-bit instruction (long) (default). 2 Soft reset Soft reset. 1: soft reset; restores default values to internal registers. Not self-clearing. Must be cleared to 0b to complete reset operation. 1 LSB first MSB or LSB data orientation. 0: data-oriented MSB first; addressing decrements (default). 1: data-oriented LSB first; addressing increments. 0 SDO active Selects unidirectional or bidirectional data transfer mode. 0: SDIO pin used for write and read; SDO set to high impedance; bidirectional mode (default). 1: SDO used for read, SDIO used for write; unidirectional mode. 0x003 [7:0] Part ID (read only) Uniquely identifies the dash version (-0 through -4) of the AD9518. AD9518-0: 0x21. AD9518-1: 0x61. AD9518-2: 0xA1. AD9518-3: 0x63. AD9518-4: 0xE3. 0x004 0 Read back active registers Selects register bank used for a readback. 0: reads back buffer registers (default). 1: reads back active registers. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |