| поискавой системы для электроныых деталей |
|
AFS090 датащи(PDF) 148 Page - Microsemi Corporation |
|
|
|||||||||||||||||||||||||||||
AFS090 датащи(HTML) 148 Page - Microsemi Corporation |
|
148 / 334 page ![]() Device Architecture 2- 13 2 R e v isio n 2 Table 2-57 details the settings available to control the prescaler values of the AV, AC, and AT pins. Note that the AT pin has a reduced number of available prescaler values. Table 2-58 details the settings available to control the MUX within each of the AV, AC, and AT circuits. This MUX determines whether the signal routed to the ADC is the direct analog input, prescaled signal, or output of either the Current Monitor Block or the Temperature Monitor Block. Table 2-59 details the settings available to control the Direct Analog Input switch for the AV, AC, and AT pins. Table 2-60 details the settings available to control the polarity of the signals coming to the AV, AC, and AT pins. Note that the only valid setting for the AT pin is logic 0 to support positive voltages. Table 2-57 • Prescaler Control Truth Table—AV (x = 0), AC (x = 1), and AT (x = 3) Control Lines Bx[2:0] Scaling Factor, Pad to ADC Input LSB for an 8-Bit Conversion2 (mV) LSB for a 10-Bit Conversion2 (mV) LSB for a 12-Bit Conversion2 (mV) Full-Scale Voltage Range Name 000 1 0.15625 64 16 4 16.368 V 16 V 001 0.3125 32 8 2 8.184 V 8 V 010 1 0.625 16 4 1 4.092 V 4 V 011 1.25 8 2 0.5 2.046 V 2 V 100 2.5 4 1 0.25 1.023 V 1 V 101 5.0 2 0.5 0.125 0.5115 V 0.5 V 110 10.0 1 0.25 0.0625 0.25575 V 0.25 V 111 20.0 0.5 0.125 0.03125 0.127875 V 0.125 V Notes: 1. These are the only valid ranges for the Temperature Monitor Block Prescaler. 2. LSB voltage equivalences assume VAREF = 2.56 V. Table 2-58 • Analog Multiplexer Truth Table—AV (x = 0), AC (x = 1), and AT (x = 3) Control Lines Bx[4] Control Lines Bx[3] ADC Connected To 0 0 Prescaler 0 1 Direct input 1 0 Current amplifier temperature monitor 1 1 Not valid Table 2-59 • Direct Analog Input Switch Control Truth Table—AV (x = 0), AC (x = 1), and AT (x = 3) Control Lines Bx[5] Direct Input Switch 0 Off 1 On Table 2-60 • Voltage Polarity Control Truth Table—AV (x = 0), AC (x = 1), and AT (x = 3)* Control Lines Bx[6] Input Signal Polarity 0 Positive 1 Negative Note: *The B3[6] signal for the AT pad should be kept at logic 0 to accept only positive voltages. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |