53 / 90 page ![]() Analog Integrated Circuit Device Data 53 Freescale Semiconductor 33910 ELECTRICAL CHARACTERISTICS STATIC ELECTRICAL CHARACTERISTICS MC33910BAC / MC34910BAC STATIC ELECTRICAL CHARACTERISTICS Table 33. Static Electrical Characteristics Characteristics noted under conditions 5.5 V ≤ VSUP ≤ 18 V, -40°C ≤ TA ≤ 125°C for the 33910 and -40°C ≤ TA ≤ 85°C for the 34910, unless otherwise noted. Typical values noted reflect the approximate parameter mean at TA = 25°C under nominal conditions, unless otherwise noted. Characteristic Symbol Min Typ Max Unit SUPPLY VOLTAGE RANGE (VS1, VS2) Nominal Operating Voltage VSUP 5.5 – 18 V Functional Operating Voltage(84) VSUPOP – – 27 V Load Dump VSUPLD – – 40 V SUPPLY CURRENT RANGE (VSUP = 13.5 V) Normal Mode (IOUT at VDD = 10 mA), LIN Recessive State (85) IRUN – 4.5 10 mA Stop Mode, VDD ON with IOUT = 100 µA, LIN Recessive State(85), (86), (87) 5.5 V < VSUP < 12 V VSUP = 13.5 V ISTOP – – 48 58 80 90 µA Sleep Mode, VDD OFF, LIN Recessive State(85), (87) 5.5 V < VSUP < 12 V 12 V ≤ VSUP < 13.5 V ISLEEP – – 27 37 35 48 µA Cyclic Sense Supply Current Adder(88) ICYCLIC – 10 – µA SUPPLY UNDER/OVER-VOLTAGE DETECTIONS Power-On Reset (BATFAIL)(89) Threshold (measured on VS1)(88) Hysteresis (measured on VS1)(88) VBATFAIL VBATFAIL_HYS 1.5 – 3.0 0.9 3.9 – V VSUP under-voltage detection (VSUV Flag) (Normal and Normal Request modes, Interrupt Generated) Threshold (measured on VS1) Hysteresis (measured on VS1) VSUV VSUV_HYS 5.55 – 6.0 1.0 6.6 – V VSUP over-voltage detection (VSOV Flag) (Normal and Normal Request modes, Interrupt Generated) Threshold (measured on VS1) Hysteresis (measured on VS1) VSOV VSOV_HYS 18 – 19.25 1.0 20.5 – V Notes 84. Device is fully functional. All features are operating. 85. Total current (IVS1 + IVS2) measured at GND pins excluding all loads, Cyclic Sense disabled. 86. Total IDD current (including loads) below 100 µA. 87. Stop and Sleep mode currents will increase if VSUP exceeds 13.5 V. 88. This parameter is guaranteed by process monitoring but, not production tested. 89. The flag is set during power up sequence. To clear the flag, a SPI read must be performed. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |