| поискавой системы для электроныых деталей |
|
ST7LNB1Y0 датащи(PDF) 12 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
ST7LNB1Y0 датащи(HTML) 12 Page - STMicroelectronics |
|
12 / 36 page ![]() Functional description ST7LNB1Y0 12/36 3.2.1 Command signalling In order to be detected, the DiSEqC-ST commands must be sent after a voltage change from 13 to 18 V. A delay time, t, between 4 ms and 24 ms must be respected before sending the DiSEqC-ST commands (see Figure 8). Figure 8. Signalling of the DiSEqC-ST command Table 7. ODU_SaTCR_Inst(5Bh) Sub-command DATA1 DATA2 Command Description 7 6 5 4 32 10 ODU_Config(1) SaTCR 0 00 01 AppliNum(2) This command is sent by an RTA-STB in order to determine the ST7LNB1Y0 application number. ODU_Lofreq(3) SaTCR 0 00 10 LOfreqNum(4) This command is sent by the RTA-STB in order to determine the L.O frequencies present in the LNB. ODU_SaTCRxSignalOn xx 00 xxh When receiving this command the ST7LNB1Y0 commands all the SaTCRs to send a tone in order to indicate their respective BPF center frequencies. 1. ODU_Config: When receiving this command the ST7LNB1Y0 checks if the Polonium indicated in data1 corresponds to the ST7LNB1Y0 application number, if it is the case the ST7LNB1Y0 commands SaTCR indicated in data1 to send a tone having as frequency F = FbpfSaTCR else F = FbpfSaTCR + 20 MHz. 2. AppliNum: application number [1 to FFh] (refer toTable 11). 3. ODU_Lofreq: When receiving this command the ST7LNB1Y0 checks if the LOfreqNum indicated in data1 corresponds to the one of the L.Os present in the application, if it is the case the ST7LNB1Y0 commands SaTCR indicated in data1 to send a tone having as frequency F = FbpfSaTCR else F = FbpfSaTCR + 20 MHz. 4. LofreqNum: Local oscillator table entry number [1 to FFh] (refer to Table 10). Table 8. DiSEqC-ST command examples LNB DiSEqC Frame Description ODU_Config E0 00 5B 01 02 The STB asks if the application number is 2, the reply tone is expected from SaTCR1. ODU_Lofreq E0 10 5B 42 04 The STB asks if the LO frequency number 4 is present on the LNB, the reply tone is expected from SaTCR3. ODU_Change_Channel E0 00 5A 24 55 The STB asks for a channel_change on SaTCR2 with a Tuning = 055h from matrix RF input = Feed1. 13 V 18 V DiSEqC-ST Frame 24 ms ≥ t ≥ 4 ms ~ 1ms |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |