| поискавой системы для электроныых деталей |
|
IXP45X датащи(PDF) 136 Page - Intel Corporation |
|
|
|||||||||||||||||||||||||||||
IXP45X датащи(HTML) 136 Page - Intel Corporation |
|
136 / 148 page ![]() Intel® IXP45X and Intel® IXP46X Product Line of Network Processors—Datasheet Intel® IXP45X and Intel® IXP46X Product Line of Network Processors Datasheet August 2006 136 Document Number: 306261-004US Table 75. HPI-16 Non-Multiplexed Read Accesses Values Symbol Parameter Min . Max. Units Notes Tadd_setup Valid time that address is asserted on the line. The address is asserted at the same time as chip select. 11 45 Cycles 1, 5, 6 Tcs2hds1val Delay from chip select being active and the HDS1 data strobe being active. 3 4 Cycles 5, 6 Thds1_pulse Pulse width of the HDS1 data strobe 4 5 Cycles 2, 4, 5 Tdata_setup Data is valid from the time from of the falling edge of HDS1_N to when the data is read. 45 Cycles 3, 5, 6 Trecov Time required between successive accesses on the expansion interface. 217 Cycles 4, 6 Notes: 1. The address phase parameter (T1) must be set to a minimum value of 2. This value allows three T clocks for the address phase. This setting is required to ensure that in the event of an HRDY, the IXP45X/IXP46X network processors have had sufficient time to recognize the HRDY and hold the address phase for at least one clock pulse after the HRDY is de-active. 2. The data setup phase parameter (T2) must be set to a minimum value of 2. This value allows three T clocks for setup phase. 3. The data strobe phase parameter (T3) must be set to a minimum value of 1. This value allows two T clocks for the data phase. This setting is required to ensure that in the event of an HRDY, the IXP45X/ IXP46X network processors have had sufficient time to recognize the HRDY and hold the data setup phase for at least one clock pulse after the HRDY is de-active 4. Setting the recovery phase parameter (T5) will adjust the duration between successive accesses on the Expansion Bus interface. 5. HRDY can be asserted by the DSP at any point in the access. The interface will not leave states T1 or T3 until HRDY is de-active 6. One cycle is the period of the Expansion Bus clock. 7. Timing was designed for a system load between 5pF and 60pF for high drive setting Figure 40. HPI*-16 Non-Multiplexed Read Mode B-01 Valid Valid Data Valid Data Valid T1 T3 T4 T3 T2 T1 T2 T5 EX_ADDR[23:0] (ha) EX_RDY_N (hrdy) EX_DATA (hdout) EX_CS_N (hcs_n) EX_WR_N (hds1_n) EX_RD_N (hr_w_n) EX_CLK Tadd_setup Tdata_setup Thds1_pulse Tcs2hds1val Trecov |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |