| поискавой системы для электроныых деталей |
|
41210 датащи(PDF) 21 Page - Intel Corporation |
|
|
|||||||||||||||||||||||||||||
41210 датащи(HTML) 21 Page - Intel Corporation |
|
21 / 52 page ![]() Datasheet — 41210 Bridge 21 3.1.6.2 Differential Receiver (RX) DC Input Specifications Table 16 defines the DC specifications of parameters for all differential Receivers (RXs). The parameters are specified at the component pins. 1. Specified at the measurement point and measured over any 250 consecutive UIs. The test load in Figure 2, “Compliance Test/Measurement Load” on page 23 should be used as the RX device when taking measurements (also refer to the Receiver Compliance Eye Diagram as shown in Figure 3, “Minimum Receiver Eye Timing and Voltage Compliance Specification” on page 23). If the clocks to the RX and TX are not derived from the same clock chip the TX UI must be used as a reference for the eye diagram. 2. The receiver input impedance shall result in a differential return loss greater than or equal to 15 dB and a common mode return loss greater than or equal to 6 dB over a frequency range of 50 MHz to 1.25 GHz. This input impedance requirement applies to all valid input levels. The reference impedance for return loss measurements for is 50 Ω to ground for both the D+ and D- line (i.e., as measured by a Vector Network Analyzer with 50 Ω probes - see Figure 2). Note: that the series capacitors C TX is optional for the return loss measurement. 3. Impedance during all operating conditions. 4. The Rx DC Common Mode Impedance that must be present when the receiver terminations are first enabled to ensure that the Receiver Detect occurs properly. Compensation of this impedance can start immediately and the (ZRX-COM-DC)RxDC Common Mode Impedance must be with in the specified range by the time Detect is entered. 5. The Rx DC Common Mode Impedance that exists when the receiver terminations are disabled or when no power is present. This helps ensure that the Receiver Detect circuit will not falsely assume a receiver is powered on when it is not. Table 16. Differential Receiver (RX) DC Input Specifications Symbol Parameter Min Nom Max Units Comments VRX-DIFFp-p Differential Input Peak to Peak Voltage 0.17 5 1.20 0 V VRX-DIFFp-p = 2*|VRX-D+ - VRX-D-| See Note 1. VRX-CM-ACp AC Peak Common Mode Input Voltage 150 mV VRX-CM-AC= |VRX-D+ + VRX-D-|/2– VRX-CM-DC VRX-CM-DC = DC(avg) of |VRX-D++VRX-D-|/2 during L0 See Note 1. RLRX-DIFF Differential Return Loss 15 dB Measured over 50 MHz to 1.25 GHz See Note 2. RLRX-CM Common Mode Return Loss 6dB Measured over 50 MHz to 1.25 GHz See Note 2 ZRX-DIFF-DC DC Differential Input Impedance 80 100 120 W RX DC Differential Mode impedance. See Note 3. ZRX-COM- DC DC Input Common Mode Input Impedance 40 50 60 W RX DC Common Mode impedance 50 ?+/-20% tolerance. See Notes 1 and 3. ZRX-COM- INITIAL-DC Initial DC Input Common Mode Input Impedance 550 60 W RX DC Common Mode impedance allowed when the receiver terminations are first powered on. See Note 4. ZRX-COM- HIGH-IMP- DC Powered Down DC Input Common Mode Input Impedance 200 k W RX DC Common Mode impedance when the receiver terminations are not powered (i.e., no power). See Note 5. VRX-IDLE- DET-DIFFp- p Electrical Idle Detect Threshold 65 175 mV VRX-IDLE-DET-DIFFp-p =2*|VRX-D+ - VRX-D-| Measured at the package pins of the Receiver. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |