| поискавой системы для электроныых деталей |
|
SC312XDP512F0MPVR датащи(PDF) 548 Page - Freescale Semiconductor, Inc |
|
|
|||||||||||||||||||||||||||||
SC312XDP512F0MPVR датащи(HTML) 548 Page - Freescale Semiconductor, Inc |
|
548 / 1348 page ![]() Chapter 13 Periodic Interrupt Timer (S12PIT24B4CV1) MC9S12XDP512 Data Sheet, Rev. 2.21 548 Freescale Semiconductor 13.3.0.6 PIT Time-Out Flag Register (PITTF) Read: Anytime Write: Anytime (write to clear); writes to the reserved bits have no effect 13.3.0.7 PIT Micro Timer Load Register 0 to 1 (PITMTLD0–1) Read: Anytime Write: Anytime 76543210 R 0000 PTF3 PTF2 PTF1 PTF0 W Reset 00000000 = Unimplemented or Reserved Figure 13-8. PIT Time-Out Flag Register (PITTF) Table 13-6. PITTF Field Descriptions Field Description 3:0 PTF[3:0] PIT Time-out Flag Bits for Timer Channel 3:0 — PTF is set when the corresponding 16-bit timer modulus down-counter and the selected 8-bit micro timer modulus down-counter have counted to zero. The flag can be cleared by writing a one to the flag bit. Writing a zero has no effect. If flag clearing by writing a one and flag setting happen in the same bus clock cycle, the flag remains set. The flag bits are cleared if the PIT module is disabled or if the corresponding timer channel is disabled. 0 Time-out of the corresponding PIT channel has not yet occurred. 1 Time-out of the corresponding PIT channel has occurred. 76543210 R PMTLD7 PMTLD6 PMTLD5 PMTLD4 PMTLD3 PMTLD2 PMTLD1 PMTLD0 W Reset 00000000 Figure 13-9. PIT Micro Timer Load Register 0 (PITMTLD0) 76543210 R PMTLD7 PMTLD6 PMTLD5 PMTLD4 PMTLD3 PMTLD2 PMTLD1 PMTLD0 W Reset 00000000 Figure 13-10. PIT Micro Timer Load Register 1 (PITMTLD1) Table 13-7. PITMTLD0–1 Field Descriptions Field Description 7:0 PMTLD[7:0] PIT Micro Timer Load Bits 7:0 — These bits set the 8-bit modulus down-counter load value of the micro timers. Writing a new value into the PITMTLD register will not restart the timer. When the micro timer has counted down to zero, the PMTLD register value will be loaded. The PFLMT bits in the PITCFLMT register can be used to immediately update the count register with the new value if an immediate load is desired. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |