| поискавой системы для электроныых деталей |
|
PIC16F722-E/ML датащи(PDF) 119 Page - Microchip Technology |
|
|
|||||||||||||||||||||||||||||
PIC16F722-E/ML датащи(HTML) 119 Page - Microchip Technology |
|
119 / 302 page ![]() © 2009 Microchip Technology Inc. DS41341E-page 119 PIC16F72X/PIC16LF72X TABLE 12-5: WDT/TIMER1 GATE INTERACTION 12.6.3 TIMER1 GATE TOGGLE MODE When Timer1 Gate Toggle mode is enabled, it is pos- sible to measure the full-cycle length of a Timer1 gate signal, as opposed to the duration of a single level pulse. The Timer1 Gate source is routed through a flip-flop that changes state on every incrementing edge of the signal. See Figure 12-4 for timing details. Timer1 Gate Toggle mode is enabled by setting the T1GTM bit of the T1GCON register. When the T1GTM bit is cleared, the flip-flop is cleared and held clear. This is necessary in order to control which edge is measured. 12.6.4 TIMER1 GATE SINGLE-PULSE MODE When Timer1 Gate Single-Pulse mode is enabled, it is possible to capture a single pulse gate event. Timer1 Gate Single-Pulse mode is first enabled by setting the T1GSPM bit in the T1GCON register. Next, the T1GGO/DONE bit in the T1GCON register must be set. The Timer1 will be fully enabled on the next incrementing edge. On the next trailing edge of the pulse, the T1GGO/DONE bit will automatically be cleared. No other gate events will be allowed to increment Timer1 until the T1GGO/DONE bit is once again set in software. Clearing the T1GSPM bit of the T1GCON register will also clear the T1GGO/DONE bit. See Figure 12-5 for timing details. Enabling the Toggle mode and the Single-Pulse mode simultaneously will permit both sections to work together. This allows the cycle times on the Timer1 Gate source to be measured. See Figure 12-6 for timing details. 12.6.5 TIMER1 GATE VALUE STATUS When Timer1 Gate Value Status is utilized, it is possi- ble to read the most current level of the gate control value. The value is stored in the T1GVAL bit in the T1GCON register. The T1GVAL bit is valid even when the Timer1 Gate is not enabled (TMR1GE bit is cleared). 12.6.6 TIMER1 GATE EVENT INTERRUPT When Timer1 Gate Event Interrupt is enabled, it is pos- sible to generate an interrupt upon the completion of a gate event. When the falling edge of T1GVAL occurs, the TMR1GIF flag bit in the PIR1 register will be set. If the TMR1GIE bit in the PIE1 register is set, then an interrupt will be recognized. The TMR1GIF flag bit operates even when the Timer1 Gate is not enabled (TMR1GE bit is cleared). WDTE TMR1GE = 1 and T1GSS = 11 WDT Oscillator Enable WDT Reset Wake-up WDT Available for T1G Source 1 NY Y Y N 1 YY Y Y Y 0 YY N N Y 0 NN N N N Note: Enabling Toggle mode at the same time as changing the gate polarity may result in indeterminate operation. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |