| поискавой системы для электроныых деталей |
|
XRP7708 датащи(PDF) 19 Page - Exar Corporation |
|
|
|||||||||||||||||||||||||||||
XRP7708 датащи(HTML) 19 Page - Exar Corporation |
|
19 / 27 page ![]() X XR RP P7 77 70 08 8 Q Qu ua ad d C Ch ha an nn ne ell D Diig giitta all P PW WM M S Stte ep p D Do ow wn n C Co on nttrro olllle err © 2010 Exar Corporation 19/27 Rev. 1.0.3 within +/- 5% of the external clock frequency. A higher Main Oscillator frequency will not improve accuracy or any performance efficiency. PWM SWITCHING FREQUENCY CONSIDERATIONS There are several considerations when choosing the PWM switching frequency. Minimum On Time Minimum on time determines the minimum duty cycle at the specific switching frequency. The minimum on time for the XRP7708 is 40ns. % 100 As an example the minimum duty cycle is 4% for 1MHz PWM frequency. This is important since the minimum on time dictates the maximum conversion ratio that the PWM controller can achieve. % Maximum Duty Cycle The maximum duty cycle is dictated by the minimum required time to sample the current when the low side MOSFET is on. For the XRP7708, the minimum required sampling time is about 16 clock cycles at the main oscillator frequency. When calculating maximum duty cycle, the sampling time needs to be subtracted using the below equation. For example, if operating at 1MHz using the 32MHz main oscillator frequency, the maximum duty cycle would be: % 1 16 0.03 100 47% On the other hand, if the 48MHz main oscillator frequency was chosen for the 1MHz PWM frequency, the maximum duty cycle would be: % 1 16 0.03 100 64% Therefore, it is best to choose the highest main oscillator frequency for a particular PWM frequency if duty cycle limit might be encountered. The maximum duty cycle for any PWM frequency can easily be determined using the following table: Main Oscillator Frequency Maximum Duty Cycle 48MHz 44.8MHz 41.6MHz 38.4MHz 35.2MHz 32MHz 28.8Mhz 25.6MHz 47% 1.5MHz 1.4MHz 1.3MHz 1.2MHz 1.1MHz 1.0MHz 900KHz 800KHz 64% 1.0MHz 933KHz 867KHz 800KHz 733KHz 667KHz 600KHz 533KHz 72% 750KHz 700KHz 650KHz 600KHz 550KHz 500KHz 450KHz 400KHz 77% 600KHZ 560KHz 520KHz 480KHz 440KHz 400KHz 360KHz 320KHz 80% 500KHz 467KHZ 433KHz 400KHz 367KHz 333KHz 300KHz NA 83% 429KHZ 400KHZ 370KHz 343KHz 314KHz NA NA NA 85% 375KHz 350KHz 325KHz 300KHz NA NA NA NA Fig. 21: PWM Frequency It is highly recommended that the maximum duty cycle obtained from the table above be programmed into each of the channels using the SET_DUTY_LIMITER_CHx register. This ensures that under all conditions (including faults), there will always be sufficient sampling time to measure the output current. When the duty cycle limit is reached, the output voltage will no longer regulate and will be clamped based on the maximum duty cycle limit setting. Efficiency |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |