18 / 30 page ![]() Analog Integrated Circuit Device Data 18 Freescale Semiconductor 33784 FUNCTIONAL DEVICE OPERATION LOGIC COMMANDS AND REGISTERS Normally enhanced long responses will be sent for enhanced long commands, and enhanced short responses will be sent for enhanced short commands of the same length. If an enhanced long word is sent after an enhanced short word, or an enhanced short word is sent after an enhanced long word, or two enhanced short words of different lengths are sent in succession, then the first response will have a different length than the second command, and therefore the first response will be invalid. LOGIC COMMANDS AND REGISTERS INTRODUCTION The following sections describe in detail each of the commands that can be sent to the 33784. All of these commands can be sent in long-word format (standard or enhanced). Some of the commands can be sent in short- word format (standard or enhanced), but not all. Refer to the table in each section for the available formats for each command. The responses for each command can also be found in the tables. The 4-bit CRC, which is appended to every command and every response, has been omitted. Many commands have “don't-care” bits, which can be set to 0 or 1 without affecting the command. Although the 33784 will respond the same in either case, it is recommended that all “don't-care” bits be set to 0 to maintain future compatibility. INITIALIZATION COMMAND AND RESPONSE (BUSIN INPUT ONLY) Following power-up or after a POR has occurred, the Initialization Command must be sent to the 33784 before it will respond to other commands. The command format is found in Figure 9. The Initialization Command may be used to initialize a daisy chain device. The Initialization Command is sent to address zero. The command will be received by the next daisy chain device with its bus switch open. Reception of this command will assign the device address and close the bus switch if the BSH and BSL bits are logic [1] Once a device has received an Initialization Command, it will ignore further initialization commands unless it has received a clear command or undergone a power-ON reset. The response is sent during the next message following a valid Initialization Command to the addressed device. The response is shown in Figure 9. Because this is a long-word only command, there is no short word response. The BSH and BSL bits returned are the same as the bits sent in the command. The Request Status command can be used to find the logic commanded state of the bus switches. Figure 9. Initialization Command Response Format REQUEST STATUS COMMAND AND RESPONSE This command causes the addressed device to return the status of the BSH and BSL bits and the logic levels of the I/ O. The command format is found in Figure 10. The 33784 will only act on this command if the address bits in the command match the address that the device was initialized with. If the addresses do not match, the device will do nothing and no response will be generated. Data Address Command Word Type – BSH BSL OD PA3 PA2 PA1 PA0 A3 A2 A1 A0 0 0 0 0 LW Not Valid SW & ESW (8-bit) Not Valid ESW (10-bit) Response Word Type A3 A2 A1 A0 0 0 0 0 0 BSH BSL 0 PA3 PA2 PA1 PA0 LW No Response SW & ESW (8-bit) No Response ESW (10-bit) Legend A[3:0] = Address bits. The slave address. An address value of 0000 is ignored by all devices (no initialization, no bus switch closure, and no response) BSH = High Side Bus Switch Position (1 = closed). BSL = Low Side Bus Switch Position (1 = closed). “–” = Don’t care bit. Can be 0 or 1. PA[3:0] = Bus address to set the device to. An address value of 0000 is ignored by all devices (no initialization, no bus switch closure, and no response) OD = Oscillator dither: 0 = no dither (default) 1 = dither |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |