22 / 30 page ![]() Analog Integrated Circuit Device Data 22 Freescale Semiconductor 33784 FUNCTIONAL DEVICE OPERATION LOGIC COMMANDS AND REGISTERS Figure 14. I/O Control Command and Response Format REQUEST ID COMMAND AND RESPONSE This command will cause the device ID information to be read from internal storage and returned to the master. The command format is found in Figure 15. The response is sent during the next message following a valid Request ID command to the addressed device. Because this is a long-word only command, there is no short word response. The 33784 will only act on this command if the address bits in the command match with the address that the device was initialized. If the addresses do not match, the device will do nothing and no response will be generated. Figure 15. Request ID Command and Response Format Data Address Command Word Type – L2 L1 L0 – DR2 DR1 DR0 A3 A2 A1 A0 0011 LW & ELW Not Valid SW & ESW (8-bit) Not Valid ESW (10-bit) Response Word Type A3 A2 A1 A0 00000 L2 L1 L0 0 DR2 DR1 DR0 LW & ELW No Response SW & ESW (8-bit) No Response ESW (10-bit) Legend A[3:0] = Address bits. DR[2:0] = I/O direction bits. 1 = Output. All bits are set to 0 by reset/clear. “–” = Don’t care bit. Can be 0 or 1. L[2:0] = Level to output on I/O if configured as outputs. Data Address Command Word Type –––––––– A3 A2 A1 A0 0100 LW & ELW Not Valid SW & ESW (8-bit) Not Valid ESW (10-bit) Response Word Type A3 A2 A1 A0 0000 V3 V2 V1 V0 000 FPA R LW & ELW No Response SW & ESW (8-bit) No Response ESW (10-bit) Legend A[3:0] = Address bits. The address of the selected device. An address value of 0000 is ignored by all devices. “–” = Don’t care bit. Can be 0 or 1. V[3:0] = Device version number. The silicon version number of the device. V0 always = 0, indicating MC33784 FPAR = Some parameters in the device are trimmed by fuses. Since these parameters can be impacted by the state of the fuses a fuse parity is calculated and stored during device manufacturing. When the device is powered up the current fuse parity is checked against the stored parity. If they do not match this bit is set. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |