| поискавой системы для электроныых деталей |
|
LTC4098-1 датащи(PDF) 19 Page - Linear Technology |
|
|
|||||||||||||||||||||||||||||
LTC4098-1 датащи(HTML) 19 Page - Linear Technology |
|
19 / 32 page ![]() LTC4098/LTC4098-1 19 40981fb To make the CHRG pin easily recognized by both humans and microprocessors, the pin is either a DC signal of ON for charging, OFF for not charging or it is switched at high frequency (35kHz) to indicate the two possible faults. While switching at 35kHz, its duty cycle is modulated at a slow rate that can be recognized by a human. When charging begins, CHRG is pulled low and remains low for the duration of a normal charge cycle. When charge current drops to 1/10th the value programmed by RPROG, the CHRG pin is released (Hi-Z). The CHRG pin does not respond to the C/10 threshold if the LTC4098/LTC4098-1 are in VBUS current limit. This prevents false end-of-charge indications due to insufficient power available to the battery charger. If a fault occurs while charging, the pin is switched at 35kHz. While switching, its duty cycle is modulated between a high and low value at a very low frequency. The low and high duty cycles are disparate enough to make an LED appear to be on or off thus giving the appearance of “blinking”. Each of the two faults has its own unique “blink” rate for human recognition as well as two unique duty cycles for machine recognition. Table 2 illustrates the four possible states of the CHRG pin when the battery charger is active. Table 2. CHRG Signal STATUS FREQUENCY MODULATION (BLINK) FREQUENCY DUTY CYCLES Charging 0Hz 0Hz (Low Z) 100% IBAT < C/10 0Hz 0Hz (Hi-Z) 0% NTC Fault 35kHz 1.5Hz at 50% 6.25% or 93.75% Bad Battery 35kHz 6.1Hz at 50% 12.5% or 87.5% Notice that an NTC fault is represented by a 35kHz pulse train whose duty cycle toggles between 6.25% and 93.75% at a 1.5Hz rate. A human will easily recognize the 1.5Hz rate as a “slow” blinking which indicates the out of range battery temperature while a microprocessor will be able to decode either the 6.25% or 93.75% duty cycles as an NTC fault. If a battery is found to be unresponsive to charging (i.e., its voltage remains below 2.85V for 1/2 hour), the CHRG pin gives the battery fault indication. For this fault, a human would easily recognize the frantic 6.1Hz “fast” blink of the LED while a microprocessor would be able to decode either the 12.5% or 87.5% duty cycles as a bad cell fault. Because the LTC4098/LTC4098-1 are 3-terminal PowerPath products, system load is always prioritized over battery charging. Due to excessive system load, there may not be sufficient power to charge the battery beyond the bad-cell threshold voltage within the bad-cell timeout period. In this case the battery charger will falsely indicate a bad cell. System software may then reduce the load and reset the battery charger to try again. Although very improbable, it is possible that a duty cycle reading could be taken at the bright-dim transition (low duty cycle to high duty cycle). When this happens the duty cycle reading will be precisely 50%. If the duty cycle reading is 50%, system software should disqualify it and take a new duty cycle reading. OPERATION |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |