| поискавой системы для электроныых деталей |
|
A4935 датащи(PDF) 14 Page - Allegro MicroSystems |
|
|
|||||||||||||||||||||||||||||
A4935 датащи(HTML) 14 Page - Allegro MicroSystems |
|
14 / 24 page ![]() Automotive 3-Phase MOSFET Driver A4935 14 Allegro MicroSystems, Inc. 115 Northeast Cutoff Worcester, Massachusetts 01615-0036 U.S.A. 1.508.853.5000; www.allegromicro.com Fault Register All undervoltage and short faults are recorded in a 10-bit fault register as defined in table 3. The fault register accumulates all detected faults until cleared by setting RESET low, by cycling the power off and on, or by reading the contents. The contents will also be cleared if a VDD undervoltage fault is detected. During a VDD undervoltage fault condition, both fault flags will be high but all the bits in the fault register will be reset. Table 3. Fault Register Bit Definitions Bit Position Function AH First VDS exceeded on A phase high-side FET BH 2 VDS exceeded on B phase high-side FET CH 3 VDS exceeded on C phase high-side FET AL 4 VDS exceeded on A phase low-side FET BL 5 VDS exceeded on B phase low-side FET CL 6 VDS exceeded on C phase low-side FET VR 7 Undervoltage detected on VREG VA 8 Bootstrap undervoltage detected on phase A VB 9 Bootstrap undervoltage detected on phase B VC Last Bootstrap undervoltage detected on phase C The contents of the fault register can be read serially from the FF1 pin by applying a clock signal to the FF2 pin during an undervoltage or short fault state. The fault flag pins, FF1 and FF2, are open drain outputs and pas- sively pulled high when a fault is present. This makes it possible to drive one or both of these fault pins from an external source during a fault condition, when the A4935 is not pulling the pin low. FF2 can thus be used as a clock input to shift out the fault status register, bit-by-bit, on the other fault flag, FF1. When FF2 is being pulled low by the A4935, either when no fault is present or when an overtemperature fault is present, then no serial access is possible. The fault status register can be accessed only when FF2 goes high. This occurs when either a short or an undervoltage fault has been detected. Faut Register Serial Access To access the fault register, FF1 and FF2 must be monitored by an external controller. If FF2 goes high and FF1 remains low, then a short has been detected. If FF1 and FF2 go high together, then an under voltage has been detected. In either case, the sequence for reading the contents of the fault register is: 1. The external controller takes any necessary additional action to protect the FETs. 2. The external controller pulls FF2 low. 3. The A4935 outputs on FF1 the fault register first bit, AH. 4. The external controller reads the fault bit, and then cycles FF2 high then low for the next bit, BH. 5. Steps 3 and 4 alternate until all of the 10 bits in the fault regis- ter have been read out. 6. After the final bit, VC, is output, the external controller cycles FF2 high then low. 7. The A4935 resets the fault register and pulls FF1 and FF2 low to indicate no fault present. 8. The external controller releases FF2. The basic sequence for the three possible states of FF1 and FF2 are shown in figure 1. At the end of the serial transfer, on the last high-to-low transition input to FF2, the fault register and the fault flags are reset. How- ever, it is possible that one of the three unlatched fault conditions, VREG undervoltage, VDD undervoltage, or overtemperature, is still present. In this case the fault flags will immediately show the fault status. Resetting the VR Bit At power-up, on coming out of reset, or after a VDD or VREG undervoltage fault, it is possible that the fault flags and fault reg- ister will have cleared but the VR bit in the fault register remains set. This would happen if, when a power-on-reset occurred, VREG had not yet risen beyond the undervoltage threshold level, VREGUVon. Although VREG undervoltage fault state is not latched and the fault flags are cleared when the fault is removed, the VR bit in the fault register is latched and may remain set after the power-on-reset. For this reason it is recommended, when the serial fault register is to be used, to perform a reset by taking the RESET pin low for less than the reset pulse time, tRES, after the A4935 is powered-up and all fault flags are clear (FF1 and FF2 are low). |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |