| поискавой системы для электроныых деталей |
|
L99PM62XP датащи(PDF) 29 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
L99PM62XP датащи(HTML) 29 Page - STMicroelectronics |
|
29 / 98 page ![]() L99PM62XP Description Doc ID 16363 Rev 4 29/98 In order to further reduce the current consumption in standby mode, the integrated LIN bus interface offers an ultra low current consumption. Note: Use of master pull-up switch is optional. 2.8.1 Error handling The L99PM62XP provides the following 3 error handling features which are not described in the LIN Spec. V2.1, but are realized in different stand alone LIN transceivers / micro controllers to switch the application back to normal operation mode. Dominant TxDL time out If TXDL is in dominant state (low) for more than 12 ms (typ) the transmitter is disabled, the status bit is latched and can be read and optionally cleared by SPI. The transmitter remains disabled until the status register is cleared. This feature can be disabled via SPI. Permanent recessive If TXDL changes to dominant (low) state but RXDL signal does not follow within 40 µs the transmitter is disabled, the status bit is latched and can be read and optionally cleared by SPI. The transmitter remains disabled until the status register is cleared. Permanent dominant If the bus state is dominant (low) for more than 12 ms a permanent dominant status is detected. The status bit is latched and can be read and optionally cleared by SPI. The transmitter is not disabled. 2.8.2 Wake up (from LIN) In standby mode the L99PM62XP can receive a wake up from LIN bus. For the wake up feature the L99PM62XP logic differentiates two different conditions. Normal wake up Normal wake up can occur when the LIN transceiver was set in standby mode while LIN was in recessive (high) state. A dominant level at LIN for tlinbus, switches the L99PM62XP to active mode. Wake up from short to GND condition If the LIN transceiver was set in standby mode while LIN was in dominant (low) state, recessive level at LIN for tlinbus, switches the L99PM62XP to active mode. Note: A wake up caused by a message on the bus starts the voltage regulator and the microcontroller to switch the application back to normal operation mode. 2.8.3 LIN pull-up The master node pull-up resistor (1 k Ω) can be connected to Vs using the internal LIN_PU high-side switch. This high-side switch can be controlled by SPI in order to allow disconnection of the pull-up resistor in case of LIN bus short to GND conditions. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |