| поискавой системы для электроныых деталей |
|
L99LDLH32 датащи(PDF) 31 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
L99LDLH32 датащи(HTML) 31 Page - STMicroelectronics |
|
31 / 142 page ![]() DS12879 Rev 6 31/142 L99LDLH32 Functional description 141 After tDIAG_BLANK_x elapses, a failure counter starts and any channel fault is validated after N_Fails number of detected failures (also non-consecutive). The N_Fails readings are kept in memory up to N_Fails_reset (number of consecutive NOT failures detection), then the counter will be reset. Diagnostic validation strategy is applied for any possible load fault: O/LED short to ground, open string, short to VPRE_REG. If the on-time of any channel is shorter than the configured blanking time, the device automatically disables fault detection on that channel and sets the pre-regulator voltage feedback to maximum. 5.3.2 Fault bus capability In the L99LDLH32, there is 1 fault pin with "Fault Bus" capability: 1 open drain fault pin (FAULT) is associated with 1 Direct Input (DIN), output channels are mapped according to DIN_MAP_CHx. The fault pin is bidirectional, active low. Several fault pins of several devices can be connected together to have a common fault bus associated to a particular light function. This allows an automatic deactivation of complete light function in case of fault on single O/LED string only, according to the selected Fault reaction mode. There is, in fact, 1-bit (FAULT_REACT_MODEx - see FTP/RAM memory map, Chapter 7) for fault reaction mode configuration: 5.3.3 Thermal warning The L99LDLH32 integrates a temperature warning with one threshold. If the junction temperature (TJ) of the device – read by internal ADC - rises above the warning temperature threshold (TTW), the thermal warning status bit (TW – see RAM memory map, Chapter 7) is set. Thermal warning is also reported in the Global Status Byte register, in particular Global Warning (GW) bit is set. Table 7. Diagnostic blanking time DIAG_BLANK_x [1÷0] tDIAG_BLANK_x [us] 00 50 01 100 10 150 11 200 Table 8. Fault reaction mode FAULT_REACT_MODE <0> Fault Reaction Mode 0 Fault on one string => all strings of same fault bus deactivated 1 Fault on one string => no action on other strings |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |