| поискавой системы для электроныых деталей |
|
OPA2192IDRG4 датащи(PDF) 22 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
OPA2192IDRG4 датащи(HTML) 22 Page - Texas Instruments |
|
22 / 61 page ![]() ±75 ±50 ±25 0 25 50 75 ±75 ±50 ±25 0 25 50 75 100 125 150 Temperature ( ƒC) C001 6 Typical Units Shown 3 1 -3 1 -1 -0.8 -0.6 -0.4 -0.2 0 0.2 0.4 0.6 0.8 1 ±75 ±50 ±25 0 25 50 75 100 125 150 Temperature ( ƒC) C001 +3 1 -3 1 - 1 + 1 SOIC -1.1 -0.9 -0.7 -0.5 -0.3 -0.1 0.1 0.3 0.5 0.7 0.9 1.1 ±75 ±50 ±25 0 25 50 75 100 125 150 Temperature ( ƒC) C001 +3 1 -3 1 - 1 + 1 SOT and VSSOP OPA192, OPA2192, OPA4192 SBOS620E – DECEMBER 2013 – REVISED NOVEMBER 2015 www.ti.com Input Offset Voltage Drift (continued) Instead of the box method, a convenient way to illustrate input offset drift is to compute the slopes of the input offset voltage versus temperature curve. This is the same as computing the input offset drift at each point along the input offset voltage versus temperature curve. The results for the OPAx192 family are shown in Figure 51 and Figure 52. Figure 51. Input Offset Voltage Drift vs Temperature Figure 52. Input Offset Voltage Drift vs Temperature (OPA192ID and OPA2192ID) (OPA192IDBV, OPA192IDGK, OPA2192IDGK, and OPA4192IPW) As shown in Figure 51, the input offset drift is typically less than ±0.3 µV/°C over the range from –40°C to +125°C. When performing an error analysis over the full specified temperature range, use the typical and maximum values for input offset voltage drift as described in the Electrical Characteristics tables. If a reduced temperature range is applicable, use the information shown in Figure 51 or Figure 52 when performing an error analysis. To determine the change in input offset voltage, use Equation 1: ΔVOS = ΔT × dVOS/dT where • ΔVOS = Change in input offset voltage • ΔT = Change in temperature • dVOS/dT = Input offset voltage drift (1) For example, determine the amount of OPA192ID input offset voltage change over the temperature range of 25°C to 75°C for 1 σ (68%) of the units. As shown in Figure 51, the input offset drift is typically 0.15 µV/°C. This input offset drift results in a typical input offset voltage change of (75°C – 25°C) × 0.15 µV/°C = 7.5 µV . For 3 σ (99.7%) of the units, Figure 51 shows a typical input offset drift of 0.4 µV/°C. This input offset drift results in a typical input offset voltage change of (75°C – 25°C) × 0.4 µV/°C = 20 µV. Figure 53 shows six typical units. Figure 53. Input Offset Voltage Drift vs Temperature for Six Typical Units 22 Submit Documentation Feedback Copyright © 2013–2015, Texas Instruments Incorporated Product Folder Links: OPA192 OPA2192 OPA4192 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |