| поискавой системы для электроныых деталей |
|
CDCE421ARGET датащи(PDF) 20 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
CDCE421ARGET датащи(HTML) 20 Page - Texas Instruments |
|
20 / 29 page ![]() Startup Time Estimation t = REF 1 f REF Time(s) 2.27V 2.64V t pul t puh t rsu t delay t VCO_CAL t PLL_LOCK Powerup Reference Startup Delay VCOCalibration PLLLock CDCE421A SCAS873 – APRIL 2009..................................................................................................................................................................................................... www.ti.com The startup time for the CDCE421A can be estimated based on the parameters defined in Table 16 and illustrated in Figure 11. Based on these parameters, the CDCE421A startup time limits tMAX and tMIN can be calculated as shown in these equations: tMAX = tpuh + trsu + tdelay + tVCO_CAL + tPLL_LOCK tMIN = tpul + trsu + tdelay + tVCO_CAL + tPLL_LOCK Table 16. Timing Definitions: Startup Time Dependencies Parameter Definition Description Formula/Method of Determination The reciprocal of the applied reference tREF Reference Clock Period frequency (in seconds). Power-Up Time (low Power-supply rise time to low limit of Power Time required for Power Supply to tpul limit) On Reset (POR) trip point. ramp to 2.27 V. Power-Up Time (high Power-supply rise time to high limit of POR Time required for Power Supply to tpuh limit) trip point. ramp to 2.64 V. After POR releases, the Colpits oscillator is enabled. This startup time is required for the Best case: 500 µs trsu Reference Startup Time oscillator to generate the requisite signal Worst case: 800 µs (for a crystal input) levels for the delay block to be clocked by 0 s (for an LVCMOS input) the reference input. Internal delay time generated from the tdelay Delay Time reference clock. This delay provides time for tdelay = 16384 × tREF the reference oscillator to stabilize. VCO Calibration Time generated from the reference clock. This process selects the tVCO_CAL VCO Calibration Time tVCO_CAL = 550 × tREF operating point for the VCO based on the PLL settings. Time required for PLL to lock within ±10 ppm Based on the 400-kHz loop bandwidth, tPLL_LOCK PLL Lock Time of fREF. the PLL will settle in 5 τ or 12.5 µs. Figure 11. Startup Time Dependencies 20 Submit Documentation Feedback Copyright © 2009, Texas Instruments Incorporated Product Folder Link(s): CDCE421A |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |