| поискавой системы для электроныых деталей |
|
MB89R112 датащи(PDF) 35 Page - RAMXEED LIMITED |
|
|
|||||||||||||||||||||||||||||
MB89R112 датащи(HTML) 35 Page - RAMXEED LIMITED |
|
35 / 49 page ![]() MB89R112 DS411-00004-3v0-E 35 3-3. Fast Read Single Block Command The Fast Read Single Block command is the same as the Read Single Block command that reads the data stored in the specific single block. The data rate in the response is twice as defined in ISO/IEC 15693. If the Option_flag (bit 7) is “1”, the transponder adds block security status information in the response. If the Option_flag (bit 7) is “0”, the transponder returns only the data in the specified block to the reader/writer. Request [Request from the reader/writer to the transponder] Response [Response from the transponder to the reader/writer] (1) When Error_flag set (2) When Error_flag not set 3-4. Fast Write Single Block Command The Fast Write Single Block command is the same as the Write Single Block command that writes the single block data included in the request. The data rate in the response is twice as defined in ISO/IEC 15693. The transponder performs verification after writing and returns an error code if the writing has failed. If the Option_flag (bit 7) is “0”, the transponder shall return its response when it has completed the write operation starting after “t1nom (320.9 s) + a multiple of 4096/fc (302.1 s)” with total tolerance of 32/fc (2.4 s) and latest within 20 ms. If it is “1”, transponder shall wait for the reception of an EOF from the reader/ writer and upon such reception still return its response (However, if an EOF is not sent within 38 ms, the time-out occurs and the transponder can receive another command) . Request [Request from the reader/writer to the transponder] Response [Response from the transponder to the reader/writer] (1) When Error_flag set (2) When Error_flag not set SOF Flag Command (Fast Read Single Block) IC manufacturer code (necessary) UID (Addressed mode) Block number CRC EOF 8 bits 8 bits (“C0H”) 8 bits (“08H”) 64 bits 8 bits 16 bits SOF Flag Error code CRC EOF 8 bits (“01H”) 8 bits 16 bits SOF Flag Block security status(option) Data CRC EOF 8 bits (“00H”) 8 bits 256 bits 16 bits SOF Flag Command (Fast Write Single Block) IC manufacturer code (necessary) UID (Addressed mode) Block number Data CRC EOF 8 bits 8 bits (“C1H”) 8 bits (“08H”) 64 bits 8 bits 256 bits 16 bits SOF Flag Error code CRC EOF 8 bits (“01H”) 8 bits 16 bits SOF Flag CRC EOF 8 bits (“00H”) 16 bits |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |