23 / 35 page ![]() www.ti.com POWER-SUPPLY SEQUENCE AVDD REFP 29 28 2 kW 1 W 1 mF POWER-DOWN REFERENCE CIRCUIT 29 30 31 R EF P R EF M IR EF 1 W 1 W 56.2 kW 1 mF 1 mF ADS5542 SBAS308D – MAY 2004 – REVISED FEBRUARY 2007 The preferred power-up sequence is to ramp AVDD first, followed by DRVDD, including a simultaneous ramp of AVDD and DRVDD. In the event that DRVDD ramps up first in the system, care must be taken to ensure that AVDD ramps up within 10 ms. Optionally, it is recommended to put a 2-k Ω resistor from REFP (pin 29) to AVDD as shown in Figure 41. This helps to make the device more robust to power supply ramp-up timings. Figure 41. The device enters power-down in one of two ways: either by reducing the clock speed or by setting the PDN bit throught the serial programming interface. Using the reduced clock speed, power-down may be initiated for clock frequency below 2 MSPS. The exact frequency at which the power down occurs varies from device to device. Using the serial interface PDN bit to power down the device places the outputs in a high-impedance state and only the internal reference remains on to reduce the power-up time. The power-down mode reduces power dissipation to approximately 180 mW. The ADS5542 has built-in internal reference generation, requiring no external circuitry on the printed circuit board (PCB). For optimum performance, it is best to connect both REFP and REFM to ground with a 1- µF decoupling capacitor (the 1- Ω resistor shown in Figure 42 is optional). In addition, an external 56.2-kΩ resistor should be connected from IREF (pin 31) to AGND to set the proper current for the operation of the ADC, as shown in Figure 42. No capacitor should be connected between pin 31 and ground; only the 56.2-k Ω resistor should be used. Figure 42. REFP, REFM, and IREF Connections for Optimum Performance 23 Submit Documentation Feedback |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |