| поискавой системы для электроныых деталей |
|
TMP116 датащи(PDF) 35 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
TMP116 датащи(HTML) 35 Page - Texas Instruments |
|
35 / 46 page ![]() 35 TMP116, TMP116N www.ti.com SBOS740A – MAY 2017 – REVISED MAY 2019 Product Folder Links: TMP116 Submit Documentation Feedback Copyright © 2017–2019, Texas Instruments Incorporated Application Information (continued) The following methods can reduce the SHE: • System calibration removes not only the self-heating error and power-supply rejection ratio (PSRR) effect but also compensates the temperature shift caused by the thermal resistance between the device and the measured object. • If practical, use the device one-shot mode. If continuous conversion is needed, use the conversion cycle mode with significant standby time. For example, in most cases an 8-sample averaging (125 ms) with a 1- second conversion cycle provides enough time for the device to cool down to the environment temperature and removes the SHE. • Use the minimal acceptable power supply voltage. • Use a printed-circuit board (PCB) layout that provides minimal thermal resistance to the device. • Avoid using small-value pullup resistors on the SDA and ALERT pins. Instead, use pullup resistors larger than 2 kΩ. • Ensure that the SCL and SDA signal levels remain below 10% or above 90% of the device supply voltage. • Avoid heavy bypass traffic on the data line. Communication to other devices on the same data line increases the supply current even if the device is in SD mode. • Use the highest available communication speed. 8.1.1.2.3 Synchronized Temperature Measurements When four temperature measurements are needed in four different places simultaneously, triggering by reset is recommended. In this method, four devices are programed with control registers set to CC mode with a conversion cycle time of 16 s. All four devices are connected to same two-wire bus with four different bus addresses. The bus general-call reset command is issued by the master. This command triggers all devices to reset (which takes approximately 1.5 ms) and triggers a simultaneous temperature sampling according to configuration registers setting. The master has 16 seconds to read data from the devices. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |