| поискавой системы для электроныых деталей |
|
M65KG256AB датащи(PDF) 13 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
M65KG256AB датащи(HTML) 13 Page - STMicroelectronics |
|
13 / 51 page ![]() M65KG256AB 3 Commands 13/51 3.3 Bank(Row) Activate command (ACT) The Bank(Row) Activate command is used to switch a row in a specific bank of the device from the Idle to the active mode. The bank is selected by BA0 and BA1 and the row by A0 to A12 (see Table 2: Bank Selection using BA0-BA1). This command is initiated by driving KE High, VIH, with E and RAS Low, VIL, and CAS and W High. A minimum delay of tRC is required after issuing the Bank (Row) Activate command prior to initiating Read and Write operations from and to the active bank. A minimum time of tRC is required between two Bank(Row) Activate commands to the same bank (see Figure 6: Consecutive Bank(Row) Activate Command). 3.4 Read command (READ) The Read command is used to read from the memory array in Burst Read mode. In this mode, data is output in bursts synchronized with the cross points of the clock signals, K and K. The start address of the Burst Read is determined by the column address, A0 to A12, and the bank address, BA0-BA1, at the beginning of the Burst Read operation. A valid Read command is initiated by driving E and CAS Low, VIL, and W and RAS High, VIH. 3.5 Read with Auto Precharge (READA) This command is identical to the Read command except that a precharge is automatically performed at the end of the Read operation. The precharge starts tRPD (Burst Length/2 clock periods) after the Read with Auto Precharge command is input. A tRAS(min) delay elapses between the Bank (Row) Activate and the Auto Precharge commands. This lock-out mechanism allows a Read with auto Precharge command to be issued to a bank that has been activated (opened) but has not yet satisfied the tRAS(min) requirement. The DDR LPSDRAM supports the Concurrent Auto Precharge mode: a Read with auto- precharge can be followed by any command to another active bank, as long as that command does not interrupt the read data transfer, and that all other related limitations apply (e.g. contention between read data and written data must be avoided). Table 4: Minimum Delay Between two Commands in Concurrent Auto Precharge Mode shows the minimum delays between a Read with Auto Precharge command to one bank and a command to a different bank. Refer to Figure 10 for a description of Read operation with Auto Precharge. 3.6 Burst Read Terminate command (BST) The Burst Read Terminate command is used to terminate a Burst Read operation. It is issued with KE held High, by driving E and W Low and CAS and RAS High. tBSTZ after issuing the Burst Read Terminate command, DQ0-DQ15 and LDQS, UDQS revert to the high impedance state (see Figure 12: Burst Terminate During Read Operation). There is no such command for Burst Write operations. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |