| поискавой системы для электроныых деталей |
|
PCM1740E/2K датащи(PDF) 9 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
PCM1740E/2K датащи(HTML) 9 Page - Texas Instruments |
|
9 / 26 page ![]() PCM1740 9 SBAS128B www.ti.com The PLL can generate one of nine pre-programmed system clock rates for either 256fS or 384fS output. The PLL output and sampling frequencies are programmed using Control Register 3. Table I shows the available sampling frequencies and the corresponding PLL output clock rates. The reset default condition for the PLL is fS = 44.1kHz with SCKO = 384fS, or 16.9344MHz. RESET OPERATION POWER-ON RESET The PCM1740 includes power-on reset circuitry for start up initialization. The initialization sequence starts when VDD exceeds 2.2V (typical). The initialization sequence requires 1024 PLL output (or SCKO) clock cycles for completion. During initialization, both VOUTL and VOUTR are forced to VCC/ 2. Figure 6 shows the power-on reset timing, while Table II shows the reset default settings for user-program- mable functions. The user should not attempt to write control registers via the I2C-Bus interface during the initial- ization sequence. EXTERNAL RESET The PCM1740 includes an external reset input, RST (pin 10). This input may be used to force an initialization se- quence. As shown in Figure 7, the RST pin must be held low for a minimum of 20ns. The initialization sequence will then start on the rising edge of RST. Initialization requires 1024 PLL output (or SCKO) clock cycles for completion. During initialization, both VOUTL and VOUTR are forced to VCC/2. Table II shows the reset default settings for user-program- mable functions. The user should not attempt to write control registers via the I2C-Bus interface during the initial- ization sequence. SAMPLING INTERNAL SYSTEM INTERNAL SYSTEM FREQUENCY (LRCK) Clock - 256fS Clock - 384fS 16kHz Half 4.096MHz 6.144MHz 32kHz Normal 8.192MHz 12.288MHz 64kHz Double 16.384MHz 24.576MHz 22.05kHz Half 5.6448MHz 8.4672MHz 44.1kHz Normal 11.2896MHz 16.9344MHz 88.2kHz Double 22.5792MHz 33.8688MHz 24kHz Half 6.144MHz 9.216MHz 48kHz Normal 12.288MHz 18.432MHz 96kHz Double 24.576MHz 36.864MHz TABLE I. PLL Sampling and System Clock Frequencies. 1024 System Clock Periods Reset Reset Removal 2.4V 2.2V 2.0V V CC /VDD Internal Reset System Clock (SCKO) 1024 System Clock Periods Reset Reset Removal System Clock (SCKO) Internal Reset RST t RST t RST t RST ≥ 20ns FIGURE 6. Power-On Reset Operation. FIGURE 7. External Reset Operation. At power-up, the PLL requires 30ms start up time for stabilization. The PLL also exhibits a settling time of 20ms in response to changes in sampling frequency selection. The PLL output continues to operate during power-on or external reset sequences, with the sampling frequency set to fS = 44.1kHz and SCKO = 384fS. |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |